beautypg.com

EVCO EK356AJ7 User Manual

Page 3

background image

Every Contr

ol S.r

.l. • EK 356A • Sheet 2/2

8

ALARMS

8.1 Alarms

CODE

corrupted

memory

data

alarm

top probe

alarm

REASONS

there is a corruption of

the configuration data

in the memory of the

instrument

• the kind of top probe

you have connected

is not right

• the top probe plays

up

• the connection in-

strument-top probe

is wrong

• the top temperature

is outside the limits

allowed by the work-

ing range of the in-

strument

REMEDIES

turn OFF the power

supply of the instru-

ment: unless the alarm

disappears, you will

have to change the in-

strument

• look at parameter /0

• test the integrity of

the probe

• test connection in-

strument-probe

• test the temperature

close to the probe

EFFECTS

• the access to the set-

ting procedures will

not be allowed

• all outputs will be

turned OFF

the top output will be

turned OFF

The indications showed by the instrument flashes, except the indications “AL1“ and

“AL2“ (they are alternated with the top or the floor temperature) and the buzzer utters

an intermittent beep.

9

TECHNICAL DATA

9.1 Technical data

Box: self-extinguishing grey.

Size: 72 x 144 x 79 mm (2.83 x 5.66 x 3.11 in).

Installation: panel mounting, panel cut out 67 x 138 mm (2.63 x 5.43 in), with screw

brackets (supplied by the builder).

Frontal protection: IP 54.

Connections: extractable terminal blocks with pitch 7.5 mm (0.29 in) for cables up to

2.5 mm² (0.38 sq in, power supply and outputs) and with pitch 5 mm (0.19 in) for

LED minute

if it is lit, the unit of measure of the time showed by the instrument will

be minute

LED timer

if it flashes, the count of the timer for delayed starting (or the count of

the cooking timer) will be running

LED ON STAND-BY

if it is lit, the instrument will be in the STAND-BY mode (turned OFF)

MEANING

the instrument has finished counting the cooking timer

min

start

INDICAT.

the floor output will

be turned OFF

• the top output will

be turned OFF

• the floor output will

be turned OFF

no effect

no effect

• look at parameter

/0

• test the integrity of

the probe

• test connection in-

strument-probe

• test the temperature

close to the probe

turn OFF the power

supply of the instru-

ment: unless the alarm

disappears, you will

have to change the

instrument

test the temperature

close to the probe

(look at parameters

AA0, AA1 and AA4)

test the temperature

close to the probe

(look at parameters

Ab0, Ab1 and Ab4)

• the kind of floor

probe you have con-

nected is not right

• the floor probe plays

up

• the connection in-

strument-floor probe

is wrong

• the floor tempera-

ture is outside the

limits allowed by the

working range of

the instrument

there is a defect in the

cold joint of the instru-

ment

the top temperature is

outside the limit you

have set with param-

eter AA1

the floor temperature

is outside the limit you

have set with param-

eter Ab1

floor

probe

alarm

cold joint

alarm

first

tempera-

ture alarm

second

tempera-

ture alarm

AA4

1

7

---

1

kind of temperature alarm (1 = it will never be activated, 2 = absolute lower temperature

alarm, 3 = absolute upper temperature alarm, 4 = lower temperature alarm relative to the

top setpoint, 5 = upper temperature alarm relative to the top setpoint,

6 = lower temperature alarm relative to the top setpoint with automatic calculation and

enabling, 7 = upper temperature alarm relative to the top setpoint with automatic calcula-

tion and enabling)

LABEL MIN. MAX. U.M.

DEF. SECOND ALARM (it is related to the floor temperature)

Ab0

1

99

°C/°F

(7)

2

hysteresis (differential, it is relative to Ab1, it is important if Ab4 ≠ 1)

Ab1

-99

999

°C/°F

(7)

0

second temperature alarm threshold (it is important if Ab4 ≠ 1); look at Ab4 as well

Ab3

0

999

min

0

second temperature alarm exclusion time since you turn the instrument ON (it is important

if Ab4 ≠ 1)

Ab4

1

7

---

1

kind of temperature alarm (1 = it will never be activated, 2 = absolute lower temperature

alarm, 3 = absolute upper temperature alarm, 4 = lower temperature alarm relative to the

floor setpoint, 5 = upper temperature alarm relative to the floor setpoint,

6 = lower temperature alarm relative to the floor setpoint with automatic calculation and

enabling, 7 = upper temperature alarm relative to the floor setpoint with automatic calcula-

tion and enabling)

LABEL MIN. MAX. U.M.

DEF. ECONOMY/COOKING TIMER

c1

1

999

s

80

cycle time to turn ON the top output and the floor output during function Economy

(9)

c4

-1

120

s

5

time the buzzer is activated at the end of the cooking timer (-1 = the buzzer has to be silenced

by hand)

LABEL MIN. MAX. U.M.

DEF. RESERVED

L1

---

---

---

---

reserved

L2

---

---

---

---

reserved

L3

---

---

---

---

reserved

L4

---

---

---

---

reserved

(7)

the unit of measure depends on parameter /8

(8)

ds = 0.1 seconds

(9)

during function Economy top and floor output will alternatively be activated for 50 % of the time you have set with parameter.