CONFIGURATION PARAMETERS (1/2)

NOTE CODE PARAMETER

DESCRIPTION

MIN.

MAX.

U.M.

STAND.

(1)

PA

password

-55

99

---

---

/

MEASURE INPUTS

(1)

/1

calibration (ref. to the cabinet probe)

-10

+10

°

C

0

c

QUICK-COOLING/FREEZING AND COLD-STORING ON-OFF REGULATOR

(1)

c0

hysteresis (differential, ref. to the cabinet probe)

+1

+15

°

C

+2

(1)

c1

maximum length of the quick-cooling for temperature

1

400

min.

90

(1)

c2

quick-cooling for temperature cut off set (ref. to the needle probe)

-55

+99

°

C

+10

(1)

c3

cold-storing set (ref. to the cabinet probe)

-55

+99

°

C

+3

(1)

c4

maximum length of the quick-freezing for temperature

1

400

min.

270

(1)

c5

quick-freezing for temperature cut off set (ref. to the needle probe)

-55

+99

°

C

-18

(1)

c6

very cold-storing set (ref. to the cabinet probe)

-55

+99

°

C

-25

c7

threshold for needle probe properly positioned fast-test

0

+99

°

C

+30

(1)

c8

quick-cooling/freezing for temperature enabling set (ref. to the needle probe)

-55

+99

°

C

+65

c9

alarm buzzer activation length when a quick-cooling/freezing ends

0

99

sec.

3

(1)(2) cA

needle probe reading

---

---

°

C

---

(1)

cb

quick-cooling working set (ref. to the cabinet probe)

-55

+99

°

C

-10

(1)

cC

quick-freezing working set (ref. to the cabinet probe)

-55

+99

°

C

-55

(1)

cd

Hard-phase cut off set (ref. to the needle probe)

-55

+99

°

C

-15

cE

during of the needle probe properly positioned differential-test

1

99

sec.

255

(1)

cF

Hard-phase working set (ref. to the cabinet probe)

-55

+99

°

C

+15

t

HARD-PHASE DURING A QUICK-COOLING FOR TIME

C0

Hard-phase during

1

400

min.

60

C

COMPRESSOR OUTPUT PROTECTIONS

C0

disabling time at the output activation from the instrument start

0

99

min.

0

C1

disabling time at the output activation from the preceding activation

0

99

min.

0

C2

disabling time at the output activation from the preceding deactivation

0

99

min.

0

C5

cycle time for the output activation in case of cabinet probe failure

0

99

min.

10

C6

output activation length during the cold-storing in case of cabinet probe failure

0

99

min.

3

C7

output activation length during the very cold-storing in case of cabinet probe failure

0

99

min.

8

d

DEFROST REGULATOR

(3)

d0

defrost interval

0

99

hours/min.

8

(4)

d1

kind of defrost

0

2

---

1

d2

defrost cut off set (ref. to the evaporator probe)

-55

+99

°

C

+2

d3

maximum defrost length

1

99

min./sec.

30

d5

first defrost intervall from the begin of the cold-storing phase

0

99

min.

0

d4

defrost at the beginning of the quick-cooling/freezing 0=NO; 1=YES

0

1

---

0

d7

dripping length

0

99

min./sec.

2

(5)

d9

forced defrost (delays override)

0

1

---

0

(1)(2) dA

evaporator probe reading

---

---

°

C

---

(6)

db

times base for the parameters d0, d3, d7 and F5

0

1

---

0

F

EVAPORATOR FANS REGULATOR

(7)

F0

output activity

0

1

---

0

F1

output deactivation set (ref. to the evaporator probe)

-55

+99

°

C

-1

F2

hysteresis (differential, ref. to the evaporator probe)

+1

+15

°

C

+1

F3

output deactivated if the compressor is deactivated

0=NO; 1=YES

0

1

---

1

F4

output deactivated during the defrost

0=NO; 1=YES

0

1

---

1

F5

disabling time at the output activation from the end of the dripping

0

99

min./sec.

3

u

DIGITAL INPUTS

(8)

u0

door-switch activate cabinet light output

0=NO; 1=YES

0

1

---

1