beautypg.com

Carrier AQUAZONE 50VQP084-300 User Manual

Page 14

background image

14

NO

T

E

S:

1

.

Compressor and

b

lo

w

er motor ther

mally protected inter

nally

.

2

.

A

ll wir

in

g to the unit m

ust

comply with

NEC (N

ation

a

l Electr

ical

Code) and local codes

.

3

.

380/420-v tr

ansf

or

m

ers

will be

connected f

o

r 380-v oper

ation. F

or 420-v oper

ation, dis-

conn

ect VIO lead at L1, an

d attach BRN lead to L1.

Close ope

n end of VIO le

ad.

4

.

FP1 the

rmisto

r pro

v

ides

freez

e

protection f

o

r W

A

TER

. When using ANT

IFREEZE

solu-

tion,

cut JW3 ju

mper

.

5

.

T

y

pical he

at pu

mp the

rmostat

wir

ing

sho

w

n. R

ef

er

to

ther

mosta

t installation instr

uctions

for

wir

in

g to

the

unit

. T

her

mo

stat

wir

ing m

ust

be “Cla

ss 1” a

nd v

oltage

r

ating

equal to

or

g

reater t

han unit sup

ply v

oltage

.

6

.

24-v

a

lar

m signal

sho

w

n

.

F

or dr

y alar

m con

tact, cut A

L

2

DR

Y (JW4

) jumper

a

nd

d

ry

con-

tact w

ill b

e a

v

a

ilab

le betw

een AL1

and AL2.

7

.

T

ransf

or

m

er secondar

y g

ro

und via D

elux

e D

board

stan

doffs

and scre

ws to control

bo

x.

(Ground a

v

aila

b

le from top

tw

o

stan

doffs a

s

sho

wn.)

8

.

F

or

dual p

oint p

o

w

e

r option, b

lo

w

er wires (3 qty) w

ill go

to PDB2 only

.

AL

Al

ar

m Rela

y

BC

Blo

w

er Contactor

CB

Circuit Break

er

CC

Compressor C

ontactor

CO

Senso

r, C

ondensate Ov

erf

lo

w

DPP

D

u

a

l Po

in

t Po

w

e

r

DS

Disconnect Switch

FP1

Senso

r, W

ater

Coil F

reez

e Protection

FP2

Senso

r, Air C

oil F

reez

e

P

rotection

HP

High-Pre

s

sure Sw

it

ch

HPWS

Hi

gh-Pre

s

s

u

re W

a

ter

Sw

itc

h

JW3

Clippab

le

Field Selection

J

umper

LO

C

Loss of C

harge

P

ressure Switch

MV

Motor

iz

ed V

a

lv

e

PDB

P

o

w

er Distr

ib

ut

ion

Bloc

k

PDB2

P

o

w

er

Distr

ib

ut

ion Bloc

k Dual P

oint Opt

ion

RV

S

Re

v

e

rsing V

a

lv

e Solenoid

TRA

N

S

T

ransf

o

rmer

F

a

ctor

y L

ine V

o

ltag

e Wir

ing

F

actor

y L

o

w V

oltage Wir

ing

Field

Line

V

o

lta

ge Wir

ing

Field

Lo

w V

oltage Wir

ing

Pr

inted Circuit T

race

Op

tional Wir

in

g

LEGEND

Rela

y/Contactor C

oil

T

h

er

m

is

tor

Conden

sate P

an

Circuit Break

er

Ground

Sole

noid C

o

il

Rela

y Contacts - N.O

.

Rela

y Contacts - N.C

.

T

emp

er

ature Sw

itch

Switc

h

- Lo

w Pres

sure

Switc

h

- High Pressure

Wi

re Nut

Fi

g.

2

8 — 50

VQP08

4-

168

w

it

h Del

uxe

D Cont

rol

(Ty

pi

cal

)

a50-8439

D

elux

e D