EVCO EVK404N9 User Manual
Page 6

Evco S.p.A. • Code 104K404E114 • page 6/8
P9
0
4
- - - -
0
0
0
0
not avail. not avail. not avail. not avail. not avail. not avail.
P10
-199.0 9990 points
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not.avail.
0.0
0.0
P11
-199.0 9990 points
100.0 100.0
100.0
100.0 not avail. not avail. not avail. not.avail. 100.0
100.0
PAR.
MIN.
MAX. U. M.
CFG = 0 CFG = 1 CFG = 2 CFG = 3 CFG = 4 CFG = 5 CFG = 6 CFG = 7 CFG = 8 CFG = 9
r0
0.1
99.0
°C/°F (1)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
r1
-199.0 r2
°C/°F (1)
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
r2
r1
9990 °C/°F (1)
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
r3
0
1
- - - -
0
0
0
0
0
0
0
0
0
0
r6
0.1
99.0
°C/°F (1)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
r7
-199.0 r8
°C/°F (1)
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
-50.0
r8
r7
9990 °C/°F (1)
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
r9
0
1
- - - -
0
0
0
0
0
0
0
0
0
0
r11
0.0
99.0
°C/°F (1) not avail.not avail.
2.0
2.0
not avail. not avail. not avail. not avail.
2.0
not avail.
r12
0.1
99.0
°C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
2.0
not avail.
r13
0.1
99.0
°C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
2.0
not avail.
r14
0.0
99.0
°C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
2.0
not avail.
r15
0
99
min
0
0
0
0
0
0
0
not avail.
0
not avail.
r16
-99.0 99.0
°C/°F (1)
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not avail. not avail. not avail.
r17
-199.0 r18
°C/°F (3)
50.0
50.0
50.0
50.0 not avail. not avail. not avail. not avail. not avail. 50.0
r18
r17
9990 °C/°F (3)
55.0
55.0
55.0
55.0 not avail. not avail. not avail. not avail. not avail. -55.0
r19
-199.0 r20
°C/°F (3)
-55.0
-55.0
-55.0
-55.0 not avail. not avail. not avail. not avail. not avail. not avail.
r20
r19
9990 °C/°F (3)
-50.0
-50.0
-50.0
-50.0 not avail. not avail. not avail. not avail. not avail. not avail.
r21
0
99
h
not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail. not avail.
24
r23
0
2
- - - -
0
0
0
0
not avail. not avail. not avail. not avail.
0
not avail.
r24
0
240
min
0
0
0
0
not avail. not avail. not avail. not avail.
0
not avail.
r25
-199.0 9990 °C/°F (1)
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not avail.
0.0
not avail.
r26
-199.0 9990 °C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
0.0
not avail.
r27
0
240
min
0
0
0
0
not avail. not avail. not avail. not avail.
0
not avail.
r28
-199.0 9990 °C/°F (1)
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not avail.
0.0
not avail.
r29
-199.0 9990 °C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
0.0
not avail.
r30
0
240
min
0
0
0
0
not avail. not avail. not avail. not avail.
0
not avail.
r31
-199.0 9990 °C/°F (1)
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not avail.
0.0
not avail.
r32
-199.0 9990 °C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
0.0
not avail.
r33
0
240
min
0
0
0
0
not avail. not avail. not avail. not avail.
0
not avail.
r34
-199.0 9990 °C/°F (1)
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not avail.
0.0
not avail.
r35
-199.0 9990 °C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
0.0
not avail.
r36
0
240
min
0
0
0
0
not avail. not avail. not avail. not avail.
0
not avail.
r37
-199.0 9990 °C/°F (1)
0.0
0.0
0.0
0.0
not avail. not avail. not avail. not avail.
0.0
not avail.
r38
-199.0 9990 °C/°F (3) not avail.not avail. not avail. not avail. not avail. not avail. not avail. not avail.
0.0
not avail.
PAR.
MIN.
MAX. U. M.
CFG = 0 CFG = 1 CFG = 2 CFG = 3 CFG = 4 CFG = 5 CFG = 6 CFG = 7 CFG = 8 CFG = 9
C0
0
240
min
0
0
0
0
0
0
0
0
0
0
device operation in presence of probe 2 (see paragraph 4.4)
0 = no probe
1 = differential operation (only if P01 = P02) (7)
2 = operation with summer compensation of the work set-point SP1
3 = operation with winter compensation of the work set-point SP1
4 = operation with combined compensation of the work set-point SP1
probe 2 transducer minimum calibration value (only if P02 = 3 or 4)
probe 2 transducer maximum calibration value (only if P02 = 3 or 4)
REGULATORS
if CFG = 0, 1, 4, 5, 6, 7 or 8, work set-point SP1 differential
if CFG = 2, 3 or 8, differential (of the work set-point SP1) of the relays with operation
in cooling mode
minimum work set-point SP1
maximum work set-point SP1
work set-point SP1 modification block (with the procedure indicated in
paragraph 6.1)
if CFG = 2, 3 or 8, differential (of the work set-point SP1) of the relays with operation
in heating mode
if CFG = 4, 5, 6, 7 and 9 work set-point SP2 differential
if CFG = 0, 1, 2 or 3 and P9 = 4, value of the neutral area with combined
compensation operation of the work set-point SP1
minimum work set-point SP2
maximum work set-point SP2
work set-point SP2 modification block (with the procedure indicated in
paragraph 6.2)
neutral area value (of the work set-point SP1)
differential (of the work set-point SP2) of the relays operating in direct mode
differential (of the work set-point SP2) of the relays operating in inverse mode
neutral area value (of the work set-point SP2)
duration of the temporary set-point during soft switch on function
(see paragraph 4.3)
0 = no function
se P9 = 2, maximum value of the summer compensation of the work set-point SP1
se P9 = 3, maximum value of the winter compensation of the work set-point SP1
if CFG = 0, 1, 2 or 3 and P9 = 2, value of the magnitude detected by probe 2
above which summer compensation of the work set-point SP1 is started
(only if P9 = 2)
if CFG = 9, magnitude value detected by probe 2 below which the heating mode
operation is enabled
if CFG = 0, 1, 2 or 3 and P9 = 2, value of the magnitude detected by probe 2 above
which summer compensation of the work set-point SP1 is concluded
if CFG = 0, 1, 2 or 3 and P9 = 4, value of the magnitude detected by probe 2 above
which combined compensation of the work set-point SP1 is concluded (relative to
“SP2 + r6” i.e. “SP2 + r6 + r18”; consider r18 without sign)
if CFG = 9, magnitude value detected by probe 2 over which the cooling mode
operation is enabled
if CFG = 0, 1, 2 or 3 and P9 = 3, value of the magnitude detected by probe 2 below
which summer compensation of the work set-point SP1 is concluded
if CFG = 0, 1, 2 or 3 and P9 = 4, value of the magnitude detected by probe 2 below
which combined compensation of the work set-point SP1 is concluded (relative to
“SP2 + r6” i.e. “SP2 + r6 + r19”; consider r19 without sign)
value of the magnitude detected by probe 2 below which winter compensation of
the work set-point SP1 is started (only if P9 = 3)
continuous duration of the permanence of the magnitude detected by probe 2
below that established with parameter r17 (or above that established with parameter
r18) for heating mode operation (or cooling mode) to be enabled
Work Program activation/deactivation mode
0 = no function
1 = pressing the key
for 4 s
2 = activation of digital input 1 (only if i0 = 4) or digital input 2
(only if i5 = 4)
duration of the first phase of the work program
0 = on reaching the r25 value, the device will pass to the next phase
magnitude detected by probe 1 to be reached and maintained during the first phase
of the work program
magnitude detected by probe 2 to be reached and maintained during the first phase
of the work program
duration of the second phase of the work program
0 = on reaching the r27 value, the device will pass to the next phase
magnitude detected by probe 1 to be reached and maintained during the second
phase of the work program
magnitude detected by probe 2 to be reached and maintained during the second
phase of the work program
duration of the third phase of the work program
0 = on reaching the r29 value, the device will pass to the next phase
magnitude detected by probe 1 to be reached and maintained during the third
phase of the work program
magnitude detected by probe 2 to be reached and maintained during the third
phase of the work program
duration of the fourth phase of the work program
0 = on reaching the r31 value, the device will pass to the next phase
magnitude detected by probe 1 to be reached and maintained during the fourth
phase of the work program
magnitude detected by probe 2 to be reached and maintained during the fourth
phase of the work program
duration of the fifth phase of the work program
0 = the phase will continue until the function is interrupted in manual mode
magnitude detected by probe 1 to be reached and maintained during the fifth phase
of the work program
magnitude detected by probe 2 to be reached and maintained during the fifth phase
of the work program
PROTECTIONS OF THE RELAYS USED FOR REGULATION
switch-on delay of the device switch-on relays (8)