EVCO S.p.A. • Code 104X201E314 • page 5/9

12

WORKING SETPOINT AND CONFIGURATION PARAMETERS

12.1 Working setpoint

MIN.

MAX. UM

EVXV201 EVXV203EVXV204/5EVXV214/5

r1

r2

°C/°F (1)

2.0

-2.0

-18.0

-18.0

12.2 Configuration parameters
PAR.

MIN.

MAX. UM

EVXV201 EVXV203EVXV204/5EVXV214/5

SP

r1

r2

°C/°F (1)

2.0

-2.0

-18.0

-18.0

PAR.

MIN.

MAX. UM

EVXV201 EVXV203EVXV204/5EVXV214/5

CA1

-25.0 25.0

°C/°F (1)

0.0

0.0

0.0

0.0

CA2

-25.0 25.0

°C/°F (1)

not avail.

0.0

0.0

0.0

CA3

-25.0 25.0

°C/°F (1)

not avail.. not avail.

0.0

0.0

P1

0

1

- - - -

1

1

1

1

P2

0

1

- - - -

0

0

0

0

P3

0

2

- - - -

not avail.

1

1

1

P4

0

1

- - - -

not avail. not avail.

1

1

P8

0

250

ds

5

5

5

5

PAR.

MIN.

MAX. UM

EVXV201 EVXV203EVXV204/5EVXV214/5

r0

0.1

15.0

°C/°F (1)

2.0

2.0

2.0

2.0

r1

-99.0 r2

°C/°F (1)

-50.0

-50.0

-50.0

-50.0

r2

r1

99.0

°C/°F (1)

50.0

50.0

50.0

50.0

r3

0

1

- - - -

0

0

0

0

r4

0.0

99.0

°C/°F (1)

not avail. not avail.

0.0

0.0

r5

0.0

99.0

°C/°F (1)

0.0

0.0

0.0

0.0

r6

0

240

min

30

30

30

30

r7

0.0

99.0

°C/°F (1)

not avail.

10.0

10.0

10.0

PAR.

MIN.

MAX. UM

EVXV201 EVXV203EVXV204/5EVXV214/5

C0

0

240

min

0

0

0

0

C1

0

240

min

5

5

5

5

C2

0

240

min

3

3

3

3

C3

0

240

sec

0

0

0

0

C4

0

240

min

10

10

10

10

C5

0

240

min

10

10

10

10

C6

0.0

199.0 °C/°F (1)

not avail. not avail.

80.0

80.0

C7

0.0

199.0 °C/°F (1)

not avail. not avail.

90.0

90.0

C8

0

15

min

not avail. not avail.

1

1

C10

0

9.999 hr

not avail.

0

0

0

PAR.

MIN.

MAX. UM

EVXV201 EVXV203EVXV204/5EVXV214/5

d0

0

99

hr

8

8

8

8

d1

0

2

- - - -

not avail.

0

0

0

d2

-99.0 99.0

°C/°F (1)

not avail.

2.0

2.0

2.0

d3

0

99

min

30

30

30

30

d4

0

1

- - - -

0

0

0

0

d5

0

99

min

0

0

0

0

d6

0

1

- - - -

1

1

1

1

d7

0

15

min

not avail.

2

2

2

d8

0

4

- - - -

0

0

0

0

d9

-99.0 99.0

°C/°F (1)

not avail.

0.0

0.0

0.0

d11

0

1

- - - -

not avail.

0

0

0

d15

0

99

min

not avail.

0

0

0

d16

0

99

min

not avail.

0

0

0

WORKING SETPOINT
working setpoint; see also r0

WORKING SETPOINT
working setpoint; see also r0
MEASUREMENT INPUTS
offset cell probe
offset evaporator probe
offset condenser probe
Celsius degree decimal point (for size displayed during normal operation)
1 = YES
temperature unit of measurement (2)
0 = °C
1 = °F
evaporator probe function
0 = probe absent
1 = defrosting probe and probe for evaporator fan thermostatisation
2 = probe for evaporator fan thermostatisation
enabling of condenser probe
1 = YES
delay in display of variations in temperature detected by the probes
MAIN REGULATOR
working setpoint differential
minimum working setpoint
maximum working setpoint
locking of working setpoint calibration (using the procedure described in paragraph 5.2)
1 = YES
increase in temperature during Energy Saving function; see also i5, i10, HE1 and HE2
decrease in temperature during Overcooling function; see also r6
duration of Overcooling function; see also r5
minimum difference “cell temperature - working setpoint” (when the instrument switches on) such as to provoke the exclusion of the
consequent value of the evaporator temperature among the ones used for the calculation of the relative average (for the defrost activation;
only if d8 = 3); also look at d17 (3)
COMPRESSROR PROTECTION SYSTEM
delay in switching on of compressor after the insturment switches on (3) minimum time between two consecutive compressor start-ups;
also delay in compressor start-up after conclusion of cell probe error

(code “Pr1”) (4) (5)

minimum duration of compressor switch off time (4)
minimum duration of compressor switch on time
duration of compressor switch off during cell probe error (code “Pr1”); see also C5
duration of compressor switch on during cell probe error (code “Pr1”); see also C4
condenser temperature is higher than that at which the condenser overheating alarm is activated (code “COH”) (6)
condenser temperature is higher than the limit at which the compressor blocked alarm is activated (code “CSd”)
compressor alarm delay locked (code “CSd”) (7)
number of operating hours is higher than the limit at which the need for maintenance is signaled.
0 = function absent
DEFROSTING
if d8 = 0, 1 or 2, defrosting interval (8)
0 = interval defrosting will never be activated
if d8 = 3, maximum defrost interval
type of defrosting
0 = ELECTRIC - during defrosting the compressor will remain off and the defrosting output will be activated; evaporator fan activity will

depend on parameter F2

1 = BY HOT GAS - during defrosting the compressor will be switched on and the defrosting output will be activated; evaporator fan activity

will depend on parameter F2

2 = VIA STOPPING OF COMPRESSOR - during defrosting the compressor will remain switched off and the defrosting output will remain

disactivated; evaporator fan activity will depend on parameter F2

temperature at end of defrosting (only if P3 = 1); see also d3
se P3 = 0 or 2, defrosting duration
se P3 = 1, maximum defrosting duration; see also d2
0 = defrosting will not be activated
defrosting when instrument is switched on (only if d8 = 0, 1, 2 or 3) (3)
1 = YES
if d4 = 0, minimum time between switching on of instrument and activation of defrosting; see also i5 (3)
if d4 = 1, delay in activation of defrosting after instrument is switched on ; see also i5 (3)
temperature displayed during defrosting
0 = cell temperature
1 = if at the time of defrosting activation, the cell temperature is lower than the “working setpoint + r0”, at most “working

setpoint + r0”; if at the time of defrosting activation, the cell temperature is higher than the “working setpoint + r0”,
at most the cell temperature when defrosting is activated

dripping duration (during dripping the compressor will remain switched off and the defrosting output will remain disactivated; if
d16 = 0, evaporator fan activity will depend on parameter F2; if d16 ≠ 0, the evaporator fan will remain switched off)
defrosting activation methods
0 = AT INTERVALS - defrosting will be activated once the instrument has altogether been running for time d0
1 = AT INTERVALS - defrosting will be activated once the compressor has altogether been switched on for time d0
2 = AT INTERVALS - defrosting will be activated once the evaporator temperature has altogether been below temperature d9 for time d0

(visible in EVXV203, EVXV204, EVXV214, EVXV205 and EVXV215 only) (10)

3 = ADAPTABLE - defrosting will be activated when one of the following conditions is present (visible in EVXV203, EVXV204, EVXV214,

EVXV205 and EVXV215 only; also look at d0) (10):

- condition 1: the evaporator temperature will be below temperature d22 and the compressor will altogether be

switched on for time d18

- condition 2: the evaporator temperature will fall below temperature d19

4 = IN REAL TIME - defrosting will be activated at the times established in parameters Hd1 ... Hd6 (visible in EVXV214 and EVXV215 only)
evaporator temperature is higher than that at which the defrost interval counter is suspended (only if d8 = 2)
defrosting alarm switches off once maximum time limit has been reached (code “dFd”; only if P3 = 1
and in absence of an evaporator probe (code “Pr2”)
1 = YES
minimum time that the compressor must be switched on before defrosting can be activated (only if d1 = 1) (11)
predripping duration (during predripping the compressor will remain switched off, the defrosting output will be activated and the
evaporator fan will remain switched off)