Output process data block description, Output process data block-8 bit (sint) data format, Output process data block-16 bit (int) data format – Comtrol IO-Link Master EIP-4 User Manual
Page 15

IO-Link Master EtherNet/IP Reference Manual: 2000589 Rev. A
Chapter 1. EtherNet/IP Interface - 15
Output Process Data Block Description
1.3.2. Output Process Data Block Description
The contents of the Output Process Data Block are configurable.
1.3.2.1. Output Process Data Block-8 Bit (SINT) Data Format
With the Include Event to Clear option selected:
Without the Event to Clear option selected:
1.3.2.2. Output Process Data Block-16 Bit (INT) Data Format
With the Include Event to Clear option selected:
Parameter Name
Data
Description
Event to Clear
(Configurable option)
Default: Not included
INT
If included, allows clearing of 16-bit event code received in
the PDI data block via the PDU data block.
PDO Data
Default Length = 32 bytes
Array of up
to 32 BYTEs
The PDO data written to the IO-Link device. May contain
from 0 to 32 bytes of PDO data. The definition and length
of the PDO data is device dependent.
Note: Length is configurable via web page interface.
Byte
Bit 7 Bit 0
0
Event Code LSB
1
Event Code MSB
2
PDO Data Byte 0
3
PDO Data Byte 1
..
..
..
..
N+1
PDO Data Byte (N-1)
Byte
Bit 7 Bit 0
0
PDO Data Byte 0
1
PDO Data Byte 1
..
..
..
..
N-1
PDO Data Byte (N-1)
Word Bit 15 Bit 0
0
Event Code
1
PDO Data Word 0
2
PDO Data Word 1
..
..
..
..
N
PDO Data Word (N-1)