8 A 0 ^ 8 ^ 0 ^ 2

9.2 Type Specification Code

Table 9.3 Type Specification Code (Model LF470 Detector)

Model

Specification Code

Description

1 2 3 4 5

6

7

8

9 10 11 12 13 14

L F 4 7 0

LF470 Detector
Meter size

2

2.5mm (1/10”)

4

4mm (1/6”)

6

6mm (1/4”)

Assembled converter

D

LF420

E

LF230

Pipe connection port (adapter)

A

Rc(PT)l/4 female screw (standard)

B

Rc(PT)l/8 female screw

C

Rc(PT)3/8 female screw

D

Rc(PT)l/2 female screw

E

NPTl/4 female screw

Z

other

Pipe connection material

A

316 stainless steel (standard)

D

Ti (titanium)

E

Polyvinyl chloride(shock-resistant) + Ta (tantalum for) grounding ring plate

F

Polyvinyl chloride + Pt-Ir grounding ring plate

Z

Other

Gasket material

c

Fluoric rubber for acid-resistant (Standard) (Notel)

D

Fluoric rubber for alkali-resistant (Notel)

Z

other

Mounting board

A

Not provided (standard)

B

Provided (SUS304)

Flow and calibration velocity range

A

0.3 to 10 m/s (Standard range calibration)

B

0.3 to 10 m/s (Specified range calibration)

Z

other

Dedicate Preformed Cable length

A

5m (standard) (Note2)

B

5m or more (extension cable dia. 12mm, + Scotch cast connection)

C

5m or more (extension cable dia. 7mm, + Scotch cast connection) (Note2)

D

5m or more (extension cable dia. 7mm, with no connector termination) (Note2)

Coating

A

phthalic acid resin coating, pearl-gray colored (standard)

Z

other

Notel:

Consult Toshiba before ordering when choose materials at the wetting parts.

Note2: A set of cable ground sized 7mm diameter for converter is packed when the code “A”, “C” or “D” are chosen.

-