2 mounting procedure, 1 installation procedure, Caution – Toshiba LF470 User Manual
Page 14: Toshiba
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
TOSHIBA
4.2 Mounting Procedure
A
CAUTION
■ Use an appropriate device to carry
■ Turn off mains power before
and install the LF470.
working on pipes.
_ If his product falls to the
Working on pipes while
^ ^ ground, injury, of
power is applied can
malfunction of or
damage
V y cause electric shock.
DO to the product, can
be
DON’T
caused.
4.2.1 Installation Procedure
To mount the LF470, see Figure 4.1
and follow the procedures below.
(1) In case of method of piping by
nipple and union
(1-1) Connect the R female screw of the LF470 with the nipple.
(1-2) Coimect the nipple with the pipe by the union.
(2) In case of method of piping by
jont
(2-1) Connect the R female screw of the LF470 with the joint.
(2-2) Connect the Joint with the pipe
Flow direction
------------- ►
Figure 4.1 LF470 flowmeter piping connections
NOTES:
(1) Preventing from leaking, seal up R male
screw with sealant which is appropriate material to
the process fluid to be measured.
(2) Keep that the inner diameters of the
nipple, the joint and pipe on the sides of the detector larger
than that of LF470. If not, the air
bubbles will stagnate in the measuring pipe and they may dis
turb the normal measurement of flow
rate.