beautypg.com

Specifications, Fluid conductivity, Ambient temperature – Toshiba LF470 User Manual

Page 33: Structure, Toshiba

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TOSHIBA

6 ^ R 8 A 0 a 0 , 2

9. Specifications

The flowmeter specifications and the type specification code used when ordering the flowmeter

are described in this chapter.

9.1 Flowmeter Specifications

■ Overall Specifications

Meter size:

2.5mm(0.1”), 4mm(0.16”), 6mm(0.25”)

Measurement range in terms of flow velocity:

0-0.3 m/s to 0-10 m/s

System accuracy:

See the following table.

Table 9.1 System accuracy

Flow rate as a
percentage

of

range

Accuracy

0.3 -1.0 m/s

1

.0-10 m/s

50 to 100%

±0.8%ofFS

±0.8% of rate

0 to 50%

±0.4%ofFS

Note:

The accuracy above is measured under standard operating conditions at

Toshiba's calibration facility.

Fluid conductivity:

50

fxS/cm

minimum

Adaptor Material

Fluid temperature

Stainless steel and other

metal

(Standard)

-10 to +120 °C

Polyvinyl chloride

(shock-resistant)

(Option)

-10 to +60 °C

Ambient temperature:

Structure:

Power consumption:

-10 to +60 °C

IP67(NEMA4) Watertight

Converter type

Power supply

LF420

Approx. 10W(17VA)

LF230

Approx.l4W(25VA)

Fluid pressure:
Pipe joints:

-O.lMPa to IMPa

Rc(PT)l/4 female screw

Rc(PT)l/8 female screw
Rc(PT)3/8 female screw
Rc(PT)l/2 female screw
NPT 1/4 female screw

(Standard)

(Option)

(Option)
(Option)

(Option)

-

3 2

-