Specifications, Fluid conductivity, Ambient temperature – Toshiba LF470 User Manual
Page 33: Structure, Toshiba
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
TOSHIBA
6 ^ R 8 A 0 a 0 , 2
9. Specifications
The flowmeter specifications and the type specification code used when ordering the flowmeter
are described in this chapter.
9.1 Flowmeter Specifications
■ Overall Specifications
Meter size:
2.5mm(0.1”), 4mm(0.16”), 6mm(0.25”)
Measurement range in terms of flow velocity:
0-0.3 m/s to 0-10 m/s
System accuracy:
See the following table.
Table 9.1 System accuracy
Flow rate as a
percentage
of
range
Accuracy
0.3 -1.0 m/s
1
.0-10 m/s
50 to 100%
±0.8%ofFS
±0.8% of rate
0 to 50%
±0.4%ofFS
Note:
The accuracy above is measured under standard operating conditions at
Toshiba's calibration facility.
Fluid conductivity:
50
fxS/cm
minimum
Adaptor Material
Fluid temperature
Stainless steel and other
metal
(Standard)
-10 to +120 °C
Polyvinyl chloride
(shock-resistant)
(Option)
-10 to +60 °C
Ambient temperature:
Structure:
Power consumption:
-10 to +60 °C
IP67(NEMA4) Watertight
Converter type
Power supply
LF420
Approx. 10W(17VA)
LF230
Approx.l4W(25VA)
Fluid pressure:
Pipe joints:
-O.lMPa to IMPa
Rc(PT)l/4 female screw
Rc(PT)l/8 female screw
Rc(PT)3/8 female screw
Rc(PT)l/2 female screw
NPT 1/4 female screw
(Standard)
(Option)
(Option)
(Option)
(Option)
-
3 2
-