After a programmed number of minutes of inactivity, the dome camera wiii park to
preset 1. The Park Time Minutes can be set from 1 720 minutes. Setting it to 0 wiii
disable the feature.
6.5.5 PARK TIME MINUTES
To set PARK TIME MIN:
1. Enter 95 preset to access the main menu.
2. Position the cursor (^) next to PAN/TiLT SETUP and press the OPEN button to
access the Pan/Tilt menu.
3. Position the cursor next to PARK TiME MIN and press the OPEN button to move
the cursor to the right.
4. Move the joystick up or down to set the number of minutes.
5. To accept the seiection, press the OPEN button or to cancel the selection, press
the CLOSE button.
6.5.6 AUTO PATROL
The Auto Patroi feature wiii repeat a pattern of up to 64 presets. Limit stops are
ignored during Auto Patroi.
The moving speed is fixed at 300 deg/s when the STOP TIME is 10 seconds or more.
However, it wiii become 90 deg/s if a STOP time is less than 10 seconds.
To enable AUTO PATROL:
1. Enter 95 preset to access the main menu.
2. Position the cursor
( - ^ )
next to PAN/TILT SETUP and press the OPEN button to
access the Pan/Tilt menu.
3. Position the cursor next to AUTO PATROL and press the OPEN button to move the
cursor to the right.
4. Move the joystick up or down to scroll through the presets. Move the joystick left or
right to turn the preset ON or OFF.
5. To accept the selection, press the OPEN button or to cancel the selection, press
the CLOSE button.
6.5.7 SCAN SPEED
The SCAN SPEED for auto scan, random scan and frame scan can be set from 1-90
degrees/sec. However, this speed is limited by MAX SPEED.
To set SCAN SPEED:
1. Enter 95 preset to access the main menu.
2. Position the cursor (^) next to PAN/TILT SETUP and press the OPEN button to
access the Pan/Tilt menu.
- 1 8 -