2

Suitable Mounting Locations

Mount the Premier 3-Zone Controller panel near the HVAC equipment (see Figure 2). The panel can be
mounted in any orientation on a wall, stud, roof truss, or the return-air plenum. For appearance, mount the
panel level.

Remove the panel cover and use the base as a template to drill mounting holes 6.5” apart (see Figure 3).
Attach the panel with appropriate screws (not included). Use mounting anchors as needed for drywall or
plaster installations.

return air

ducts

return air

plenum

bypass

duct

coil

supply air

sensor

zone dampers

electric or

barometric

bypass damper

filtration

system

furnace

typical mounting location

6.50”

Figure 3

Figure 2