13 Installer Guide
25 Economizer, Fresh Air or Output Control [note 11] – Selects control options. Select between disabled
(NONE), economizer mode (ECON) and time of day (TOD) mode.
26 Heat Set Point Upper Limit – Selects the heating set point upper adjustment limit.
27 Cool Set Point Lower Limit – Selects the cooling set point lower adjustment limit.
28 Humidification Mode [note 12] – For use with an external humidifier. Selects between disabling
humidification (OFF), dependent control (DEP) or independent control (IND). The DEP setting controls
humidification only during a call for heating. The IND setting allows humidification output in the heat mode,
but does not require a call for heating.
NOTE: It is recommended that the IND setting only be used with
systems designed for low air temperature humidification such as steam humidification. Always ensure the
heat exchanger or other system parts are not exposed to excess water from condensation or other sources.
When there is any doubt, use the OFF or DEP setting.
29 Auto Humidity Set Point Limit [notes 10, 12] – Select between turning the automatic
humidity set point limit to auto (AUTO) or manual (MAN). When AUTO is selected, humidity control is provided
automatically based on the outdoor temperature. Selecting MAN allows you to manually control the level
of humidity.
30 Dehumidification [note 12] – For use with an external dehumidifier. Select between dehumidification
disabled (OFF), a normally inactive (NI) or normally active (NA) relay, depending on the requirements of your
external dehumidification equipment.
31 Installer Clear – Clears settings based on your selection. CLRO makes no changes, CLR1 clears all wireless
remote sensor settings and CLR2 clears
ALL thermostat settings to factory default.
WARNING: If you press NEXT or RETURN after selecting CLR1 or CLR2 the clear will take place and
the appropriate settings will be returned to factory defaults. If you do not wish to make any changes, use the
SpeedBar
®
to select CLRO.
Time Step / Override
Cooling Call
Occupied
YES or NO
ON
ON
OFF
YES
ON
OFF
OFF
NO
OFF
OFF
OFF
Override
YES or NO
ON
ON
OFF
External Air or Output Control (A)
Economizer Time of Disabled
Mode
Day Mode
Time Step / Override
Heating Call
Occupied
YES or NO
ON
ON
OFF
YES
OFF
OFF
OFF
NO
OFF
OFF
OFF
Override
YES or NO
ON
ON
OFF
External Air Output (A)
Economizer Time of Disabled
Mode
Day Mode
Unoccupied
Unoccupied