beautypg.com

Package contents, Option, Part names and functions – KEYENCE SR-1000 Series User Manual

Page 2: Startup procedure, Sample code

background image

2

E SR-1000-IM

Package Contents

Option

Part Names and Functions

Startup Procedure

Sample Code

Model

Name

Package

content

Qty.

Appearance

SR-1000/1000W

Auto focus code reader
(Fixed type)

Reader unit

1

Instruction
manual

1

Ethernet port
cover

1

Model

Name

Package

content

Qty.

Appearance

SR-H4W

Setup software
(AutoID Network
Navigator)

DVD-ROM

1

OP-87224/
87225/87226

Control cable

Cable
(2 m/5 m/10 m)

1

OP-87353/87354/
87355

Control cable
(NFPA-compliant)

Cable
(2 m/5 m/10 m)

1

OP-87527/87528/
87529

Control cable
(NFPA-compliant)
D-sub connector type

Cable
(2 m/5 m/10 m)

1

OP-87230/87231/
87232

Ethernet cable
(NFPA-compliant)

Cable
(2 m/5 m/10 m)

1

OP-51580

USB cable

Cable
(2 m)

1

OP-87866

Mounting bracket

Mounting
bracket

1

Screw (M4)

4

No.

Name

Description

(1)

Scanner

Section that reads codes.

(2)

Display

Shows reading results or reading data.

(3)

OK/ERROR LED

IIndicates whether the reading has succeeded or failed

(4)

ENTER button

Button used to confirm functions.

(5)

SELECT button

Button used to select functions.

(6)

Control port

Port for connecting the control cable.

(7)

Ethernet port

Port for connecting the Ethernet cable.

(8)

USB port

Port for connecting the USB cable for setting.

SR-1000

SEL

MENU

1

E SR-1000-IM

2D Code Reader (Fixed Type)

SR-1000 Series
Instruction manual

Introduction

Read this instruction manual before using the product in order to achieve
maximum performance.
After reading it, keep the manual always at hand for future reference.

„ Symbols

The following symbols alert you to important messages. Be sure to read
these messages carefully.

Important

It indicates cautions and limitations that must be followed during operation.

Point

It indicates additional information on proper operation.

Reference

It indicates tips for better understanding or useful information.

Indicates the reference pages in this manual or the reference pages in separate manuals.

Safety Information for SR-1000 Series

„ General Precautions

Safety Precautions on LED Product

Precautions on Proper Use

Precautions on Proper Use

„ CE Marking

Keyence Corporation has confirmed that this product complies with the
essential requirements of the applicable EC Directive, based on the
following specifications.
Be sure to consider the following specifications when using this product
in the Member State of European Union.

z EMC Directive (2004/108/EC)

• Applicable standards

EMI : EN61326-1, Class A
EMS : EN61326-1

• The length of cable connected to the power supply connector must
be less than or equal to 30 m.
These specifications do not give any guarantee that the end-product
with this product incorporated complies with the essential
requirements of EMC Directive. The manufacturer of the end-product
is solely responsible for the compliance on the end-product itself
according to EMC Directive.

z Low-Voltage Directive (2006/95/EC)

• Applicable standard : EN62471
• Indoor use only.

„ CSA Certificate

This product complies with the following CSA and UL standards and has
been certified by CSA.
• Applicable standard : CAN/CSA C22.2 No.61010-1

UL61010-1

• Be sure to consider the following specifications when using this product
as a product certified by CSA.
• Overvoltage category
• Use this product under pollution degree 2.
• Use this product at the altitude of 2000 m or less.
• Indoor use only.
• When using this product, use the following power supply.
CSA or UL certified power supply that provides Class 2 output as
defined in the CEC (Canadian Electrical Code) and NEC (National
Electrical Code), Or CSA or UL certified power supply that has been
evaluated as a Limited Power Source as defined in CAN/CSA-C22.2
No. 60950-1/UL60950-1.

„ Radio Waves Act in South Korea

Class A Equipment
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Note: This caution is effective for the Korean Radio Act only.

Ͳ 匏͑匶匶͙͑ 櫋怺殯͑愯暧皻柦匶沖沲 ͚
決͑匶匶垚͑櫋怺殯͙͑Ͳ͑匏͚͑͑洊沖砒洇穯匶匶嵢昢͑砖廪沖͑嬖垚͑斲殯沖垚͑決
洖汊渂汞穞柢匶͑愚岂彶͑͑͝儆洛歾汞͑滆櫳櫖昢͑斲殯穞垚͑冉汊͑徯洇求嵢͑穯
城埪͑͟

It indicates a hazardous situation which, if not avoided, will result in death or
serious injury.

It indicates a hazardous situation which, if not avoided, could result in death
or serious injury.

It indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.

It indicates a situation which, if not avoided, could result in product damage
as well as property damage.

Do not use this product for the purpose to protect a human body or a part
of human body.
This product is not intended for use as explosion-proof product. Do not
use this product in hazardous location and/or potentially explosion
atmosphere.

You must verify that the SR-1000 Series are operating correctly in terms of
functionality and performance before the start and the operation of the
SR-1000 Series.
We recommend that you take substantial safety measures to avoid any
damage in the event of a problem occurring.

KEYENCE never warrant the function or performance of the SR-1000
Series if it is used in a manner that differs from the SR-1000 Series
specifications contained in this instruction manual of if the SR-1000
Series are modified by yourself.
When the SR-1000 Series is used in combination with other instruments,
functions and performance maybe degraded, depending on operating
conditions and the surrounding environment.

Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
Follow the instructions mentioned in this manual. Otherwise, injury to the
human body (eyes and skin) may result.
Do not stare into the beam.
Do not disassemble this product.

LED emission from this product is not automatically stopped when it is
disassembled.
Do not view directly with optical instruments. Viewing the LED output
with certain optical instruments (for example, eye loupes, magnifiers
and microscopes) within a distance of 100 mm may pose an eye hazard.

96M13020

DANGER

WARNING

CAUTION

NOTICE

WARNING

CAUTION

NOTICE

CAUTION

Do not use a voltage other than that described in the specifications with
the SR-1000 Series. Doing so may cause damage to the unit.
Be sure to turn off the power to devices attached to the SR-1000 Series
when you plug in or unplug the cables. Failure to do so may cause damage
to the SR-1000 Series.
Do not disassemble or modify the SR-1000 Series. Doing so may cause
damage to the unit.
Place cables as far away as possible from high-voltage lines and power
lines. Otherwise, electrical noise can be generated that may cause product
failure or malfunction.
The SR-1000 Series is a precision instrument. Do not impact or drop the
instrument. Pay particular attention when transporting or installing the unit.
Do not carry the SR-1000 Series by holding its cables. This may cause cable
breaks or damage to the unit due to the impact of bumping each other.
Do not allow water, oil, dust, or other foreign substances to stick to the
scanner. This may cause read errors. Use a soft, dry cloth to wipe any
substance from the scanner. (Do not use a cloth dipped in alcohol or other
cleaning agent.)
Do not turn off the power of the SR-1000 Series while accessing files. The
internal data may be corrupted.

NOTICE

SR-1000

POWER

USB

ETHERNET

SR-1000

SEL

MENU

(1)

(2)
(3)
(4)

(5)
(6)

(7)

(8)

Top

Bottom

Step 1

Step 2

Step 3

Step 4

Step 5

DataMatrix

CODE128

POWER

DC24V

Brown

Blue

Black tube

FG

TEST MODE

1 2 3 4 5