Run Mode
Regular static elimination operation is performed in the Run mode.
The following functions are available in the Run mode.
●
Ion monitor functions
"Ion Monitor Functions" (page 8)
●
Alarm output functions
"Alarm Output Functions" (page 8)
●
Confirmation of ion balance adjustment values
Select Mode
In this mode, select the setting items to change in the Setup mode
Setup Mode
In this mode, change the settings of the items selected in the Select mode.
Blink alternately
1
424
3
Operations in the Select mode
Press
for a short time:
Enters the Setup mode for the currently selected item.
Hold down
for at least 1 second:
Exits the Select mode, and returns to the Run mode.
:
Move the cursor up and down.
On the ion monitor, the currently selected items are lit (green), and the items
whose defaults have been changed are lit (red).
Items that satisfy both of these conditions blink red and green alternately.
The following describes each of the items in the Select mode:
:Ion level alarm, sensitivity setting
:Condition alarm, sensitivity setting
:I.C.C. ON/OFF
:Initialization of settings
1
424
3
Blink alternately fast
Operations in the Setup mode
:Applies the setting at the selected conditions.
:Move the cursor up and down.
The following describes each of the items in the Setup mode:
1424
3
3-1
SJ-M Series Operations
■ Ion level alarm sensitivity setup
Sets the sensitivity at which the ion level alarm is output.
(1) High sensitivity (red):
Alarms are easily output.
(2) Medium sensitivity (orange):
(3) Low sensitivity (green):
Alarms are not easily output.
(4) No sensitivity (red):
Alarms are easily output.
Default is “Low sensitivity.”
"Ion level alarm output function (ION LEVEL)" (page 8)
■ Condition alarm sensitivity setup
Sets the sensitivity at which the condition alarm is output.
(1) High sensitivity (red):
Alarms are easily output.
(2) Medium sensitivity (orange):
(3) Low sensitivity (green):
Alarms are not easily output.
(4) No sensitivity (red):
Alarms are easily output.
Default is “Low sensitivity.”
"Condition alarm output function (COND)" (page 8)
Blink
Tip
Blink
Tip
3-1
SJ-M Series Operations
■ I. C. C. ON/OFF Setting
Advance to the I.C.C. ON/OFF setting from the Select mode in
page 7, and select either of the followings.
(1) I.C.C. ON (green) (Default)
(2) I.C.C. OFF (red)
■ Initialization of settings
Returns settings to their defaults.
(1) Press
,
or
for a short time:
Returns to the Select mode without initializing the settings.
(2) Hold down
for at least one second:
Initializes the settings and returns to the Select mode.
When settings are initialized, the ion monitor indication moves
towards both ends of the display.
Blink
Blink
When the I.C.C. OFF is selected, the ion level
alarm will not be output correctly. Ion level
monitor indication is not available, either.
Important
Blink
Tip
3-1
SJ-M Series Operations
Ion Balance Manual Adjustment Mode
In this mode, you can adjust the zero point, the point for reference for the I.C.C. function.
Ion Balance Adjustment Function
The SJ-M Series automatically senses the charged level of the target body by the I.C.C. function to
automatically control the generated amount (balance) of plus and minus ions.
The zero point, the point for reference for the I.C.C. function, is adjusted before the SJ-M Series is
shipped from the factory. However, in some environments, the zero point sometimes drifts. If this
reference zero point drifts, adequate static elimination cannot be maintained. For this reason, you need
to adjust the zero point again by “Ion Balance Adjustment Function”.
Do not turn the power OFF while the ion balance is being adjusted (about 1
minute).
■ Setting the ion balance
1
Hold down
for at least one second to enter the ion
balance manual adjustment mode.
The ion balance indicator blinks.
2
Set the ion balance using
.
The LED on the ion monitor corresponding to the set value lights.
CAUTION
Key
Function
Key
Shifts the zero point in the + direction.
Key
Shifts the zero point in the – direction.
Hold down for at
least 1 second.