beautypg.com

Using the display panel support, Specifications, Air purge unit – KEYENCE LS-9030D User Manual

Page 3: Target holder pulley, Display panel support

background image

E LS-9006D/LS-9030D

3

Using the Display Panel Support

The following describes how to mount the display panel support (OP-87757)

to the casing.

Common to LS-9006D/LS-9030D

1

Mount the display panel support to the display panel (LS-D1000) using
the provided bolts (M4 x L10).

Maximum tightening torque for securing the unit: 0.75 N m

2

Mount the display panel support to the casing using the provided
bolts (M5 x L12).

The panel support can be mounted on either side of the casing.

Specifications

*1

A ± 2

σ

margin of error when measuring the outer diameter of

φ

1.0 mm round

bars in the center of the measurement area with the average measurement
number set as 2048 times.

*2 A ± 2

σ

margin of error when measuring the outer diameter of

φ

10 mm round

bars in the center of the measurement area with the average measurement
number set as 2048 times.

*3

Margin of error when a moving

φ

1.0 mm round bar is measured in the

measurement area.

*4

Margin of error when a moving

φ

10 mm round bar is measured in the

measurement area.

*5

The sampling frequency will vary according to the number of OUTs that have
been set and the use of the mutual interference prevention function.

z

Air purge unit

z

Target holder pulley

z

Display panel support

Model

LS-9006D

LS-9030D

Measurement target

φ

0.04 mm

φ

6 mm

φ

0.3 mm

φ

30 mm

Minimum object sensitivity

0.04 mm

0.3 mm

Repeatability

±0.03

μ

m*

1

±0.1

μ

m*

2

Measurement position

accuracy

±0.5

μ

m*

3

±2

μ

m*

4

Sampling frequency*

5

16000 times/sec

Light source

InGaN green LED

Monitor function

Unavailable

Environment

resistance

Operating

ambient

temperature

0 to + 50ºC

Operating

ambient

humidity

20 to 85% RH

(No condensation)

Ambient

luminance

Incandescent lamp/Fluorescent lamp:

3000 lx or less

Vibration

resistance

10 to 55 Hz, double amplitude 1.5 mm;

2 hrs in X, Y and Z directions

Impact

resistance

15 G/6 ms

Sensor head protection

structure

IP67 (including the connector part)

Material

Aluminum

Weight

Approx. 4.8 kg

Approx. 9 kg

Model

OP-87751

OP-87752

Material

Aluminum

Weight

Approx. 1500 g

Approx. 400 g

Model

OP-87749

OP-87750

Material

Aluminum (Main unit), SUS (Pulley part)

Weight

Approx. 300 g

Model

OP-87757

No. of mountable display panels

1

Material

Steel

Weight

Approx. 250

This manual is related to the following products: