Basic setting mode, Additional function setting mode – KEYENCE GT Series User Manual
Page 3
3
08 Static hold delay stability width
Set the range which is used to judge if the value is stable or not.
Only available when
is set to [User].
Basic setting mode
How to enter the Function setting mode
1. Press the MODE and SET button at the same time for at least 2
seconds.
2. Press the left/right arrow button and select the function number.
10 Measurement direction change
Set how the value moves, when the spindle is pressed, from [Normal]
or [Reverse].
11 Measurement direction change
Set a number if the value has to be multiplied.
12 Output format
Set the output mode from [N.O.] or [N.C.].
13 Displayed number of digits
Set the number of digits of the value.
14 Hysteresis
Set the hysteresis value.
15 Input line function 1
Set the function for input line 1(purple). [Bank A input] or [Reset input]
can be selected.
16 Input line function 2
Set the function for input line 2(pink/purple). [External timing input] or
[Bank B input] can be selected.
Additional function setting mode
How to enter the Function setting mode
1. Press the MODE and left arrow button at the same time for at least
2 seconds.
2. Press the left/right arrow button and select the function number.
20 Store preset value
Set if the preset data should be memorized or not.
21 Power save function
Select from [OFF], [ECO Half] or [ECO all].
22 Jam detection function
Set to use the Jam detection function. Jam detection function checks if
the spindle still has the ability to fully extend. Only available when
is set to [External input].
23 Check point setting
Set the reference position which is used to check if the spindle is fully
extended. Only available when
is set to [User].
24 Display filter function
Set to use the Display filter function. Display filter function makes
the response speed of the display slow, to show it stable.
[MODE]
button
[SET]
button
Main screen (P.V. value display)
Main screen (P.V. value display)
[MODE] button
Left arrow key
1114-1