Advanced setting mode – KEYENCE IL Series User Manual
Page 3
3
04 Alarm setting
Set the Alarm setting from [Default], [Clamp] or [User setting].
[Default]: When the measurement fails (out of the measurement range)
for 6(sampling rate set to 0.33ms) or 7(sampling rate set to except
0.33ms) times, the previous value is held until the next measurement is
successful.
[Clamp]: When the measurement fails (out of the measurement range),
the previous value is held until the next measurement is successful.
[User setting]: When the measurement fails (out of the measurement
range) for a certain number of times, the previous value is held until the
next measurement is successful.
05 Output state
Set the output status from [Normally Open] or [Normally Closed].
Advanced setting mode
How to enter the Advanced setting mode
1. Press the [MODE] button for at least 2 seconds.
2. Press the [MODE] or left/right arrow
button until the sub display will show
“End”.
3. Press the up/down arrow button. The
main display will show “Pro”.
4. Press the [MODE] or left/right arrow button and select the function
number.
Function
Explanation
06 Hold function
Set how to hold the value from
[Sample], [Peak], [Bottom], [Peak to
peak], [Auto peak] and [Bottom
peak].
07 Timing input
Set how the timing input for the hold
function is used from [Level] and
[Edge].
08 Delay timer
Set the delay timer for the judgment
output from [Off], [ON-delay],
[OFF-delay] and [1-shot].
09 Hysteresis
Set the hysteresis for the judgment
value.
10 Analog output scaling
Set how the analog voltage or
current should output, related to the
value.
11 External input
Assign each input function to the 4
external inputs.
12 Bank switching method
Set the way how to switch banks
from [Button] or [External input]
13 Memorizing the zero shift
Set if the shift target value has to be
memorized to the EEPROM or not,
when the zero shift was input.
14 Interference prevention
Set to use the interference
prevention function.
15 Number of digit
Set the number of digits from
[Default], [0.001], [0.01], [0.1] and
[1].
16 Power saving
Set to use the power saving
function.
17 Head display mode
Set the lighting conditions for the
light on the sensor head.
18 Display color
Set the color of the judgment light,
and the color of the main display.
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
GO
HOLD
CALC
CHECK
1114-1
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
GO
HOLD
CALC
CHECK