Dimensions, Specifications, Warranties and disclaimers – KEYENCE DL-PN1 User Manual
Page 4: Dimensions specifications, Buyer's transfer obligations
4
E DL-PN1_IM
Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.
13277E 1104-1a 96M13277 Printed in Japan
(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for
a period of one (1) year from the date of shipment. If any models or samples were shown
to Buyer, such models or samples were used merely to illustrate the general type and
quality of the Products and not to represent that the Products would necessarily conform
to said models or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection
and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will
refund the purchase price of, or repair or replace at no charge any Products found to be
defective. This warranty does not apply to any defects resulting from any action of Buyer,
including but not limited to improper installation, improper interfacing, improper repair,
unauthorized modification, misapplication and mishandling, such as exposure to
excessive current, heat, coldness, moisture, vibration or outdoors air. Components
which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are
only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products
for Buyer’s intended use. KEYENCE will not be responsible for any damages that may
result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be
used internally in humans, for human transportation, as safety devices or fail-safe
systems, unless their written specifications state otherwise. Should any Products/
Samples be used in such a manner or misused in any way, KEYENCE assumes no
responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE
harmless from any liability or damage whatsoever arising out of any misuse of the
Products/Samples.
(4)
OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE
AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY
FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY
DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION,
LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF
PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR
INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS
AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S
CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER.
In some
jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not
apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a third party,
Buyer must provide such third party with a copy of this document, all specifications,
manuals, catalogs, leaflets and written information provided to Buyer pertaining to the
Products/Samples.
E 1101-3
Dimensions
Specifications
Product name
PROFINET I/O Communication Unit
Model
DL-PN1
Suitable network
PROFINET I/O communication
Ethernet
Compliant standards
IEEE 802.3u (100BASE-TX)
Transmission rate
100 Mbps (100BASE-TX)
Transmission medium STP cable or Category 5e or higher UTP cable
(100BASE-TX)
Maximum cable
length
100 m
PROFINET
Compatible functions
Data I/O communication
Record data communication
No. of connectable
PROFINET I/O
controllers
1
Update Time
2 - 512 ms
GSDML version
V2.3
Conformance class
Conforms with Conformance Class A
Conformance test
version
Conforms with V2.2.4
Suitable protocols
LLDP, DCP
Sensor
connection
specifications
Connectable sensors
Sensor amplifiers with D-bus support
Number of
connectable sensor
units
15 units max.
Indicator lamps
Link/activity indicator (LINK/ACT): Green LED
System failure indicator (SF):
2-color (orange/red) LED
Bus failure indicator (BF): Red LED
Sensor communication indicator (D-bus):
2-color (green/red) LED
Power voltage
20 to 30 V DC ±10%, including ripple (p-p)10%
supplied from the connected sensor amplifiers
Power consumption
1500 mW or less (at 30 V 50 mA max.)
Environmental
resistance
Operating surrounding
air temperature
-20 to +55°C (no freezing)
Operating surrounding
air humidity
35 to 85% RH (no condensation)
Vibration resistance
10 to 55 Hz compound amplitude 1.5 mm, 2
hours each in X, Y, Z directions
Pollution degree
2
Materials
Main unit: Polycarbonate
Weight
Approx. 70 g
25.6
35.4
43.5
94.5
38.1
(42.5
)
29.4
(Unit : mm)