beautypg.com

Initializing settings (initial reset), Error messages, Selecting channels – KEYENCE LV Series User Manual

Page 7: Selecting output mode, Key lock, Ould, Initial settings

background image

7

LV Series-IM_E

All settings can be reset to their original values (factory defaults).
This can be done only when the operation button is not locked.

1

In the state of the received light intensity display, press

five

times, while pressing

.

2

When

is displayed on the digital LED monitor, press

once.

(When

is pressed here instead of

, the monitor returns to the received

light intensity display without being reset)

3

is displayed on the setting monitor for three seconds and

then

is displayed. Initialization is now complete. The

received light intensity display will appear on the monitor again.

Initial settings

*1: LV-51M/52/51MP/52P only
*2: For LV-51M/52/51MP/52P, FINE only

If any of the following errors appear on the LED display, check the amplifier or
sensor unit according to the countermeasures listed below.

If an error message other than the above is displayed, contact KEYENCE.

The LV Series can perform two different types of sensitivity settings.

Three types of output modes can be selected.

The operation button can be locked to prevent anyone accidentally touching the
operation button and changing settings.

„ Turning on Key Lock

Press

or

for three seconds or more while pressing

.

will start flashing on the display.

„ Releasing Key Lock

Press

or

for three seconds or more while pressing

.

will start flashing on the display.

When Key Lock is on, all settings except selecting display, selecting
output and display settings remain disabled until Key Lock is released.

This is the function of the LV-11A/21A/21AP. You cannot use this function with
LV-51M/51MP.

1

Lock the operation button

2

Connect the pink cable to a switch or PLC.

3

Making a short circuit between the pink cable and blue cable has
the same effect as pressing

.

Initializing Settings (Initial Reset)

Output A / Output B

Standard light intensity setting*1

OFF

Power mode*2

TURBO

Detection methods

Standard output 1

Display shift

Shift value: 0

Hold mode

No hold display

Timer mode

No timer

Timer

10 ms

Output setting

D. ON: 46, L. ON: 50 (52 for LV-H62)

The value for the timer is only effective when timer mode is set to
a setting other than "NO TIMER (OFF)."

Error Messages

Error message

Problem description

Countermeasures

brK

The sensor head is not
connected, sensor is inserted in
a wrong connector, or the sensor
head cable has an open circuit.

Check for an open circuit in the
head cable, and that the sensor
is connected to the correct
connector.

ouLd

Excessive current in output
cable.

Check the load and adjust to
within rated values.

Err

Data error

Perform the initial reset.

S

S

M

PH

A
B

BH

MODE SET

%

S

S

S

S

PH

A
B

BH

MODE SET

%

PH

A
B

BH

MODE SET

%

PH

A
B

BH

MODE SET

%

Point

Selecting Channels

1

Press

or

quickly

while holding down

.

2

Channel indicator for set up
mode starts flashing.

3

Release .

While tuning sensitivity or setting modes such as power mode, it
is not possible to select channels.

Selecting Output Mode

Key Lock

Adjusting Sensitivity via External Signals (External Tuning)

The operation button must be locked to perform external tuning.

Minimum input time is 20 ms.

PH

A
B

BH

MODE SET

%

One of the two channel indicators
will start flashing.

M

M

Point

PH

A
B

BH

MODE SET

%

D.ON

L.ON

L.ON

D.ON

Output switches

Switch

Output A

Output B

(Output ON when light is received)

(Output ON when

light is received)

(Output ON when

light is interrupted)

(Output ON when light is interrupted)

M

M

PH

A
B

BH

MODE SET

%

Important

S

S

LV-21A/11A

LV-21AP

Brown

Blue

Pink

+V

0V

+V

0V

Brown

Pink

Blue

Point