Menu selection, E cz-v21a(p)/v22a(p)-im – KEYENCE CZ-V22A(P) User Manual
Page 7
7
E CZ-V21A(P)/V22A(P)-IM
MENU SELECTION
Pressing the MODE button for three seconds or more displays the menu, from
which each mode can be configured.
To exit the menu during setting, press the MODE button again for three sec-
onds or more.
* For the method of selection, refer to page 6.
Selecting a function (detection mode)
Select by pressing UP or DOWN.
• C mode: Detects color based on
color components
• C+I mode: Detects color based
on color components
and light intensity
• Super I mode: Detects color based
on light intensity
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
Selecting the power saving function (Eco mode)
Select by pressing UP or DOWN.
• Normal use
• Enables the power saving function
Selecting the shift function
Select by pressing UP or DOWN.
• Normal use
• Enables the shift function
Selecting the attenuation mode
Select by pressing UP or DOWN.
• Normal use
• Lowers the light receiving sensitivity
Setting the shift target value
Set the value by pressing UP
or DOWN.
Selecting an access mode
Select by pressing UP or DOWN.
• Displays the basic menu only.
• Displays all menus.
Selecting calibration mode
Select by pressing UP or DOWN.
When the C/C+I mode is selected
• 1-point calibration
• 2-point calibration
• Pinpoint calibration
When the CZ-H72 is used
• 2-point calibration
• Base calibration
• Film calibration
Press MODE for three seconds or more
Press MODE
Press MODE
Press MODE
Press MODE
Press MODE
Press MODE
Press MODE
End of the basic
menu display
Menu display
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
Setting the timer time
Set by pressing UP or
DOWN.
Selecting a timer mode
(can be set for each bank)*
Select by pressing UP or DOWN.
• Timer OFF
• On-delay
• Off-delay
• One shot
Press MODE
Press MODE
When the access mode is selected as FULL
When timer
is selected
as OFF
When timer is
other than OFF
When the Super
I detection mode
is selected or the
CZ-H52 is used
When the C/C+I
detection mode is
selected or the
CZ-H72 is used
When the C/C+I
detection mode is
selected or the
CZ-H72 is used
When the Super I detection
mode is selected or the
CZ-H52/H72 is used
When the
shift function
is selected
as off
When the shift
function is
selected as on
End of menu
display
A
B
BANK
1 2 3 4
C
A
B
BANK
1 2 3 4
C
Selecting a power mode (response time)
Select by pressing UP or DOWN.
• HIGH SPEED: 200
µs
• FINE: 1ms
• TURBO: 4ms
• SUPER: 8ms
Press MODE
Selecting an output mode
(can be set for each channel)*
Select by pressing UP or DOWN.
• Turns on at light green
(Turns on when the light
enters)
• Turns on at a color other
than light green
(Turns on when the light
is shielded)
The display inside the parentheses is when the Super
I mode is selected or the CZ-H52/H72 is used.
When using
the CZ-H52/H72
When using the
CZ-H32/H35S/H37S