3 Initial Settings

When you turn on the LR-TB Series for the first time after you purchase it or when you have
initialized the LR-TB Series, the following initial settings must be configured.

After you have finished configuring the initial settings, you will not be able to reconfigure the
unit, I/O, or NPN/PNP selection. To change any of these settings, you will have to initialize the
product.

"Initialization" (page 7)

.

3-1. I/O Selection

Select from the following table the functions assigned to the I/O wires (black and white).

The functions assigned to output 1, output 2, and external input can be changed after you
finish configuring the initial settings.

"6 Detailed Settings" (page 8).

3-2. External Input Selection

„

Transmission OFF [Laser Off]

The laser beam transmission is stopped.

„

External Calibration [Tuning]

When selected, this external input performs the same function as pressing the [SET]
button.

„

Reference surface update [DATUM Preset]

When the detection mode (

"4 Detection Mode" [page 4]) is set to "DATUM mode," this

external input updates the reference surface.

3-3. NPN/PNP Selection

You can select between NPN outputs or PNP outputs. For details, see

"Wiring" (page

2).

mm
inch
feet

and

Display Units

Press for 3 seconds or more

Start Config.

Select I/O

Select Input

Select Output

End Config.

RUN

NPN

NPN
PNP

Laser Off

Laser Off
Tuning
DATUM Preset

Out1+Out2

Out1+Out2

Input+Out1

Input+Out1

1234

500

1

2

Out1+Out2

3-1. I/O Selection
(

page 3)

3-2. External Input
Selection
(

page 3)

3-3. NPN/PNP
Selection
(

page 3)

Options

Black Wire

White Wire

Out1 + Out2

Output 1

Output 2

Input + Out1

External input

Output 1

Transmission

Transmission

OFF

Input

ON

< 5 ms

< 50 ms

OFF

Input

ON

> 60 ms

> 60 ms

OFF

Updated reference surface

Updated output

Input

ON

> 5 ms

< 60 ms

Response

time

OFF