5000 Series Indicators
8. TECHNICAL DATA
8.1 Specifications
Materials
T51XW Housing: stainless-steel
T51P Housing: ABS plastic
Display window: polycarbonate
Keypad: polyester
Feet: Rubber
Ambient conditions
The technical data is valid under the following ambient conditions:
Ambient temperature: -10°C to 40°C / 14°F to 104°F
Relative humidity: Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50%
relative humidity at 40°C.
Height above sea level: up to 2000m
Operability is assured at ambient temperatures between -10°C and 40°C.
Indicator
T51P
T51XW
Maximum Displayed Resolution
1:30,000
Maximum Approved Resolution
1:10,000
Maximum Counting Resolution
1:300,000
Weighing Units
kg, lb, g, oz, lb:oz, tonnes, custom
Functions
Static Weighing, Dynamic Weighing, Counting, Checkweighing, Percent Weighing
Display
25 mm / 1 in High 6-digit, 7-segment LCD
Over/Accept/Under Indicators
Red, Green, Yellow LED
Backlight
White LED
Keypad
4-button membrane switch
Ingress Protection
---
IP66
Load Cell Excitation Voltage
5V DC
Load Cell Drive
Up to 8 x 350 ohm Load Cells
Load Cell Input Sensitivity
Up to 3 mV/V
Stabilization Time
Within 2 Seconds
Auto-zero Tracking
Off, 0.5, 1 or 3 Divisions
Zeroing Range
2% or 100% of Capacity
Span Calibration
1 kg or 1 lb to 100% Capacity
Housing Dimensions (W x D x H)
(mm/in)
260 x 71 X 168 / 10.2 x 2.7 x 6.6
262 x 76 x 149 / 10.3 x 3.0 x 5.8
Net Weight (kg/lb)
1.5 / 3.3
3.5 / 7.7
Shipping Weight (kg/lb)
2.3 / 5
4.3 / 9.5
Operating Temperature Range
-10°C to 40°C/14°F to 104°F
Power
100-240 VAC / 50-60 Hz Internal Universal Power Supply,
6 C-type batteries (T51P)
Interface
Built-in RS232 and External Input
TABLE 8-1. SPECIFICATIONS