5000 Series Indicators

3.2 Menu Navigation

3.3 Calibration Menu

When CAL is displayed, press the Yes button to accept the Calibration menu
selection. Press the No button to advance to the desired calibration menu item.
Three calibration processes are available: Zero Calibration, Span Calibration and
Linearity Calibration. Default settings are bold.

Zero Perform
Span Perform
Linearity Perform
Cal Test Perform
Geographic
Adjustment Set 00…Set 12…Set 31
End Calibration Exit CALIBRATE menu

NOTES:
1. Make sure that appropriate calibration masses are available before
beginning calibration.
2. Make sure that the scale base is level and stable during the entire
calibration process.
3. Calibration is unavailable with LFT set to ON.
4. Allow the Indicator to warm up for approximately 5 minutes after
stabilizing to room temperature.
5. To abort calibration, press the Exit button anytime during the calibration
process.
6. When any selection within the GMP menu is enabled, calibration results
are automatically printed.

Enter the menu by pressing the TARE

Menu button until MENU is displayed. When the button is released,

the Legal for Trade status is displayed, followed by the first menu. Press the No or Back button to move to a
different menu. Press the Yes button to enter the menu. Once in the menu, press the Yes button to view the
menu item setting or press the No or Back button to move to the next menu item. When viewing the setting,
press the Yes button to accept the setting, or press the No or Back button to change the setting. Once all
settings have been made, press the Exit button to return to the current application mode.

For menu items with numeric settings such as Capacity, the current setting is displayed with all digits flashing.
Press the No button to begin editing.
The first digit is displayed flashing.

Press the No button to increment the digit or press the Yes button to accept the digit and move to the next digit.

Repeat this process for all digits.

Press the Yes button when the last digit has been set.

The new setting is displayed with all digits flashing. Press the Yes button to accept the setting or press the No
button to resume editing.

This method also applies to setting Checkweigh under and over targets.

For End menu items, pressing the Yes button advances to the next menu, while pressing the No button returns