Hardy HI 1769-FC User Manual
Page 39

34
●
●
●
●
●
Chapter 4
Parameter
#hex
/Sub#
Default
Brief Description (Note: Expanded description are
listed below)
100% rate
6032 None
This is the MAX RATE that the system can
achieve. Maximum rate is calculated from the rate
calibration data.
7 Rate Cal
Percentages
xx33
7 rate calibration percents.
Uses 2 decimal places. 0.00-100.00
0 Percent
0033
0.00
MIN percentage value required to start the feeder,
calculated from the other calibrated points.
1st Percent
1033
20.00
A 5 point auto-rate calibration ends at this value.
This is not used in a 2 point calibration
2nd Percent
2033
30.00
Fourth value to be run in a 5 point calibration or
the second value to be run in a 2 point calibration.
3rd Percent
3033
40.00
Third value to be run in a 5 point calibration. This
is not used in a 2 point calibration
4th Percent
4033
60.00
Second value to be run in a 5 point calibration or
the first point in a 2 point calibration
5th Percent
5033
80.00
A 5 point auto-rate calibration start at this
programmed value
100 Percent
6033
100.00
MAX percentage value = 100%
End Rate Calibration Section
ADC Average
34
None
0x0034 // Read Only
STATE 35
None
0x0035 // Read Only
Mode
Value
IDLE_MODE 0
AUTO_MODE 1
MANUAL_MODE 2
START_MODE 3
STOP_MODE 4
SHUT_OFFMODE 5
PAUSE_MODE
6
RATE_CAL_MODE 7
REFILL_MODE 8
FULL_MODE
9
MANUAL_HOLD_MODE
10
RATECAL_HOLD_MODE 11
INITIAL_REFILL_MODE
12
MANUALOP
37
None
Two decimal places. This it the output percent
when in MANUAL mode.
FAST_ROC
38
None
Lightly averaged rate of change, read only, RATE
decimal places.
zerocount 0x0A00
None
AD counts at zero weight
calLowCount 0x0A01
None
Numbers or letters in the titles below correspond to the values in Column 2, Hex#, above
Parameter 2
Metric (Unit of Measure)
The Unit parameter sets the scale and related displays to one of the following options: