Axial Piston: Type of design for hydraulic motors and pumps in which the pistons are arranged
parallel with the spindle (input or output shaft).

Bantam Duty: A descriptive term relating to the product capacity (meaning: light duty).

Bypass Valve: A valve whose primary function is to open a path for the fl uid to bypass the motor
or pump. Also referred to occasionally as the freewheel valve or dump valve.

Case Drain Line (Return Line): A line returning fl uid from the component housing to the res-
er voir.

Cavitation: A concentrated gaseous condition within the fl uid causing the rapid implosion of a
gas eous bubble.

Center Section: A device which acts as the valve body and manifold of the transmission.

Charge Pump: A device which supplies replenishing fl uid to the fl uid power system (closed
loop).

Charge Pressure: The pressure at which replenishing fl uid is forced into a fl uid power system.

Charge Relief Valve: A pressure control valve whose primary function is to limit pressure in the
charge circuit.

Check Valve: A valve whose primary function is to restrict fl ow in one direction.

Closed Loop: A sealed and uninterrupted circulating path for fl uid fl ow from the pump to the
motor and back.

Decay Rate: The ratio of pressure decay over time.

End Cap: See “Center Section”

Entrained Air: A mechanical mixture of air bubbles having a tendency to separate from the liquid
phase.

Gerotor: A positive displacement pump frequently used as a charge pump.

Hydraulic Motor: A device which converts hydraulic fl uid power into mechanical force and mo-
tion by transfer of fl ow under pressure.

Hydraulic Pump: A device which converts mechanical force and motion into hydraulic fl uid pow er
by producing fl ow.

Hydrostatic Pump: See “Hydraulic Pump”

SECTION 6. GLOSSARY OF TERMS