Discharge Chute and Controls (Electric)
125
Discharge Chute
1.
Remove the hair pin clip that secures the shaft to the
Remote Head. See Figure 11.15.
2.
Remove the bow tie clip.
3.
Remove the clevis pin that holds the Remote Head to
the Support Bracket. See Figure 11.16.
4.
Remove the wing nut.
NOTE: Units with a steel chute have a lock nut instead of a
wing nut. See Figure 11.17.
NOTE: Units with a steel chute have the nut, for the bolt
that attaches the Remote Head to the chute,
exposed. It must be held with a 7/16” wrench
during step 5.
Figure 11.15
Hair Pin Clip
Figure 11.16
Bow Tie Clip
Wing Nut
Figure 11.17
Lock Nuts