35


SOFT ADDRESS SET 

 
The  use  can  set  up  the  SOFT  ADDRESS,  SOFT  PROTOCOL  and   
SOFT  BAUD  RATE  under  this  menu  here  to  activate  the  soft 
address  function.  And  then  the  defined  dome  address  by  dip 
switch will be disabled. 
 
1) Move  the  cursor  to  INPUT  (under  DOME  ID)  and  press  IRIS 

OPEN to enter the mode of setting dome ID, Move the joystick 
to position  the cursor beside :0 1  2 3 4  5  6  7  8 9” and press 
IRIS  OPEN  to  enter.  And  move  the  joystick  again  to  select 
numbers  of  dome  ID  and  press  IRIS  OPEN  to  confirm.  The 
number selected will be input on the upper line. 

 
2) Move the cursor to INPUT (the bottom menu) and press IRIS 

OPEN  to  enter  the  mode  of  setting  soft  address,  Move  the 
joystick to position the cursor beside :0 1 2 3 4 5 6 7 8 9” and 
press IRIS OPEN to enter. And move the joystick again to select 
numbers of dome soft address and press IRIS OPEN to confirm. 
The number selected will be input on the upper line. 

 
3) Enable  or  disable  the  soft  address  function.  Press  IRIS  CLOSE 

to 

exit 

last 

step. 

Move 

the 

cursor 

to 

to 

“SOFTADDRESS:ON/OFF”.  Press  iris  open  to  enter.  Move  the 
joystick  up  or  down  to  select  ON  of  OFF.  Press  IRIS  OPEN  to 
confirm. 

 
4) Press  OK  to  save  and  confirm  all  the  settings  and  press 

CANCEL to exit all the settings.