IR Speed Dome Operating Manual

21

ALARM

The dome system has 2alarm inputs and 1 alarm

output. (optional function). When an alarm is received, an
input signal to the dome triggers the user defined action
(such as presets, patterns, etc.), and at meantime the
alarm output signals is activated.

ALARM NO.: Move the cursor to the ALARM NO. Press IRIS OPEN to
enter and move the joystick up and down to select the alarm input
no. (Channel 1 and Channel 2)

INPUT STATE: Set the alarm contact status. There are two input
states, OPEN and CLOSE.

ALARM MODE:

ACTION: Set the alarm action:

ALARM OUT: Set the auxiliary to activate:

RESET TIME: Set up time for the alarm output (such as an alarm
buzzed) when is triggered by the detector.

START /STOP TIME: Set up the time to start alarm and stop alarm
ONLY under the AUTO mode under ALARM MODE.

OFF

Alarm function is deactivated.

ON

Alarm function is activated.

AUTO

AUTO Alarm function will be activated and deactivated
between START TIME and STOP TIME.

NONE

(default) No action

PRESET

Dome goes to preset. (Default as Preset 1)

SCAN

Dome starts auto scan (Default as Auto Scan 1)

SEQ

Dome runs auto cruise (Default as Auto Cruise 1)

PATTERN

Dome runs pattern (Default as Pattern 1)

OFF

Not alarm output will be activated.

OUT1

An alarm action will close AUX 1 output..

OUT2

An alarm action will activate AUX2 output.

MAIN MENU

LANGUAGE :ENGLISH





RESTART
FACTORY DEFAULTS

HELP
EXIT

DOME SETTINGS









RESTART
FACTORY DEFAULTS

BACK

EXIT

ALARM SETTING

ALARM NO. :1
CONTACT :N/O
INPUTSTATE :OPEN
ALARM MODE :OFF
ACTION :NONE
ALARM OUT :OFF
RESET TIME :10 SEC
START TIME:00:00
STOP TIME:00:00

BACK

EXIT