Brookfield Bath, Model TC-602 User Manual

Page 3

background image

2

!

This symbol marks chapters and sections of this instruction manual which are particularly relevant to safety. When
attached to the unit, this symbol draws attention to the relevant section of the instruction manual.

!

!

This symbol indicates that hazardous voltages may be present.

!

!

:$&;!&--!/+)'%,0'/(+)!#$%'&/+/+1!'(!)&9$'<=!)$'>,#=!&+;!(#$%&'/(+?!

5%(#$%!(#$%&'/(+!/)!'3$!,)$%)@!%$)#(+)/7/-/'

!

$0'/(+!!>!$+$%&-!+9(%6&'/(+!

?!

+#&0/+1!
Your circulator is shipped in a special carton. Retain the carton and all packing materials until the
unit is completely assembled and working properly. Set up and run the unit immediately to confirm
proper operation. Beyond one week, your unit may be warranty repaired, but not replaced. If the
unit is damaged or does not operate properly, contact the transportation company, file a damage
claim and contact the company where your unit was purchased.

Remove any loose packing material that may have fallen into the reservoir during shipping. Before
powering up, check that nothing remains around the heater or circulator pump.

The instructions in this manual pertain to circulating baths both refrigerated and cooling coil types.
Read the section pertaining to the special instructions for your model.

?!!

.(+'$+')!!

Circulator Bath

TC-102P

TC-202P

TC-502P

TC-602P

TC-900P

Operators Manual, warranty
card

110-242

RS-232 Communication Cable

RSS-E1

3

/

16

in., ¼ in., and

3

/

8

in. Nylon

Barbed Tubing Adapters

510-011

6 ft. of ¼ in. ID Latex Tubing

HT-Tubing

Adapter Fittings*

¼ in. NPT – M16, Male (qty 2)

Beaker Platform(s) for Bath
Reservoir

— 600 ml

— 1000ml

701-402

701-402 (qty 2)

701-403

701-402

701-402

Deck Lid(s)

— Solid

— w/Beaker Holes

510-209
510-211

510-210

510-290
510-293

510-246

510-484

Blue Hole Plugs

— 3

1

/

2

inch

— 4 ¼ inch

Note: Do Not Use Above 120°C

TBPS300-295

TBPS300-295

(qty 2)

TBPS300-296

TBPS300-295

IEC Power Cord

(qty 1)

Note: Work area "opening" is designed to measure samples directly in the bath. If additional viscometer height is
required (spindle/guard clearance), either a 4 inch rod extension (part number BLM-4E) used with type A lab stand
or an 18 inch rod replacement (part number VS-38) used with type S lab stand are available from Brookfield or an
authorized dealer.

* Included with 50Hz Models only.