Example C

Initial Bath Temperature = 25°C
Program Priority = Temperature

Desired Profile: Cool bath temperature to 20°C as fast as possible.

Increase bath temperature to 55°C as fast as possible.

Repeat 7 times.

This example requires a 2-step program with the number of loops set to 8:

Program

Step

Step Set

Point

Step

Duration

Controller Operation

1

20°C

1 second

Controller cools fluid to 20°C as fast as possible. Until
20°C temperature set point is achieved, “Starting”
appears on the display.

When fluid temperature reaches 20°C, “Running” appears
on the display.

Controller applies heat until 55°C set point for Step 2 is
reached.

2

55°C

1 second

Controller loops back to Step 1, applying cooling until
20°C set point is reached.

Steps 1 and 2 repeat seven more times. When the last
loop has been completed, “Complete” appears on the
display. Fluid temperature is maintained at 55°C until the
set point is changed.