68 •
•
•
•
Interface Wiring
Remote Control
This connection is dedicated to a 360 Systems RC-320 Remote Control with a D-SERIAL-320 Remote
Control interface cable. This port communicates with the remote control and also provides power to it.
PIN
SIGNAL
1
GND
2
+5 VOLTS (Not normally used)
3
GND
4
TX + (DigiCart Transmitter, wire to RX+)
5
TX – (DigiCart Transmitter, wire to RX-)
6
Remote Present RTN
7
+12V
8
GND
9
N/C
10
N/C
11
RX + (DigiCart Receiver, wire to TX+)
12
RX - (DigiCart Receiver, wire to TX-)
13
Remote Present signal
14
+12V
15
GND
Remote Bus
This connection is dedicated to 360 Systems RC-210/220 Remote Controls and/or the RC-210/220/320
Control Bus daisy-chain.
PIN
SIGNAL
1
GND
2
+5 VOLTS (Not normally used)
3
GND
4
TX + (DigiCart Transmitter, wire to RX+)
5
TX – (DigiCart Transmitter, wire to RX-)
6
HSK OUT (Not normally used)
7
HSK IN (Not normally used)
8
RX + (DigiCart Receiver, wire to TX+)
9
RX - (DigiCart Receiver, wire to TX-)
This connection can also be used as an input for control by automation systems. It should not be used as an
input any time the Remote Control connection is in use such as when an RC-320 is connected.