Monitoring a recording source with e-e mode – 360 Systems MAXX-2420EX User Manual
Page 44
Page 44
MAXX-2420-EX Owner’s Manual
Figure 12 - Channel 1 Ready to Record
• Click the RECORD button at any time to begin recording. The yellow time display counters
will update the clip duration continually.
• To stop recording, click STOP.
Note: An in-progress recording must be 2 seconds long before it will appear in the clip list. Hitting
the STOP button to end the recording after less than 2 seconds will also cause the clip to appear in
the clip list.
Monitoring a Recording Source with E-E Mode
The E-E button appears in the Channel 1 and Channel 2 Record/Play window. It allows the input
signal to be monitored from the server output. E-E Mode toggles automatically as described
below, but can also be switched manually at any time.
When a new clip is created for recording, the input source is automatically switched ON to the
output—an E-E connection. When a clip is opened for play on Channel 1 or 2, E-E monitoring is
switched OFF.
When Channel 1 or 2 is switched to playlist mode, the E-E monitor is switched OFF. E-E mode
cannot be toggled while the channel is in playlist mode.
When E-E is ON, the input video signal is routed to the outputs. Manually toggle the E-E mode
button OFF to switch the output to the servers output, for conventional playback operation.