Connection, Setting – Panasonic WZ-AD96 User Manual
Page 37
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
C o n n e c t i n g t h e S y s t e m
C
onnecting
with
P
ro
T
ools
(C
onnection
4)
Wordclock master: Pro Tools
888 I/O
•
Connection
1. Connect SLAVE CLOCK OUT on the
888 I/O #1 and SLAVE CLOCK IN on
the
888 I/O #2 with a BNC cable. Then connect between #2 and #3 in
the same way as
#1 and #2.
2. Connect SLAVE CLOCK OUT on the
888 I/O #3 to WCK In on the DA
converter with a BNC cable.
3. Connect WCK Out on the DA converter and WCK In on the AD converter
#1 with a BNC cable. Then, connect between Wordclock-Out on the AD
converter #1 and Wordclock-In on the AD converter
#2
with a BNC cable.
In the same manner connect the AD converter #2, #3 and the DA
converter with BNC cables.
4. Connect AES/EBU Out on the AD converter #1 and AES/EBU In on the
888
I/O #1 with XLR cables. For #2 and #3 connect in the same manner.
5. Connect between the AES/EBU Out on the
888 I/O #1 and AES/EBU In on
the DA converter with XLR cables to monitor the sound.
Setting
1. Set SYNC MODE to “INTERNAL”, and select SAMPLE RATE from 44.1k or
48k on the
888 I/O #1.
2. Set Channel 1-8 INPUT to “DIGITAL”, and 1-2 FORMAT to “AES/EBU”on the
888 I/O #1-3.
3. On the AD converter select “EXT” by pressing the CLOCK button, and set
the DIP switch #7 to On and
#8 to Off to meet the REF level to -18 dBFS.
See “REF Level Setting”.
38