A d j u s t m e n t & S e t t i n g
TX
M
ode
S
election
Data transmission formats are selected to meet the connected device’s and
system requirements.
•
AES/EBU Output
Select an output mode by DIP switch #1 on the rear panel.
The high sampling signal has a double density information than
the normal. There are two transmission modes extended form the
normal AES/EBU Tx mode. The AD converter transmits either one
of extended modes.
Tx mode
Channel/Wire
7a:
Rate
Typical device
AES/EBU(Normal)
2
44.1/48 kHz
Dual AES
(Dual Wire)
1
44.1/48 kHz
MTRs
Cenex Recorder
Hi-speed
(Single Wire)
2
88.2/96 kHz
Processors
Tc Electronics
y
•
Dual AES Output Card
This is an option card to enable the AD converter supplying
8 channel
output in Dual AES/EBU mode.
•
ADAX TDIF Output
An optical output : Dual track mode, 24 bit, 96 kHz, 4 channel is supplied.
•
Output channel
Selecting CHl-4 or CH5-8 is implemented in SHIFT operation mode.
WoRDCLOCK S
election
Wordclock In setting is required.
•
Wordclock In
The AD Converter examines input wordclcok frequency to have the internal
system clock synchronized to the input: 44,1, 88.2, 48 or 96 kHz. Contrary to
the Wordclock In, sampling frequency is selected manually on the front panel
by pressing the FREQ button.