C o n n e c t i n g t h e S y s t e m

C

onnecting

with

TDRS (C

onnections

)

Wordclock master: WZ-AD96/96M AD Converter

Connection

1. Install the TDIF card, an option to the AD converter, into the rear slot.

See instructions attached to the card for more details.

2. Connect between Wordclock-Out on the AD converter and WCK IN on the

DA converter with a BNC cable. In addition connect WCK THRU on the DA

converter and WORD SYNC In on the DA

88 converter with a BNC cable.

Note that inside the AD converter both CN907 and 908 jumpers are set to

“OUT” positions.

3. Connect TDIF Out on the AD converter and TDIF In on the DA

88 with a

DB25 Y cable as illustrated. In addition connect one end of the DB25 Y

cable to the TDIF In on the DA converter to monitor the sound. See page
40 for detailed information on DB25 Y cable.

Setting

1. On the AD converter, select “CRYSTAL” by pressing the CLOCK button,

then select a sampling rate by pressing the FREQ button. Note that if

88.2

or 96 kHz is selected , move the DIP switch

#6 to On to keep sending

44.1 or 48 kHz wordclock to the DA

88.

2. Set the DIP switch on the AD converter #7 to Off and

#8 to On to meet

the REF level to -16 dBFS. See “REF Level Setting”.

3. On the DA

88, select “WORD” by pressing the CLOCK switch to let it sync

to the wordclock.

4. On the AD converter, select output channels: 1-4 or 5-8; after entering the

SHIFT operation mode if 88.2 or 96 kHz is used. The selected channel
outputs will be recorded on the DA

88’s tracks: output channels “1, 2, 3

and 4” or “5,

6, 7 and 8” will be recorded onto track 1/2, 3/4, 5/6 and 7/8

respectively.

(1) To enter the SHIFT operation mode press the WORD LENGTH button

for

2 second or more.

(2) Press the FREQ button to select output channels. The FREQ LEDs

indicate the selection.

CH 1-4: The FREQ LED 44.1k/88.2k lights.

CH 5-8: The FREQ LED 48k/96k lights.

5. On the DA

88’s front panel, press the DIGITAL IN switch to receive digital

audio input.

3 6