S
elf
D
iagnosis
The diagnosis program examines following items.
• Press the POWER switch while holding down the [FREQ/CH SEL] and
[WORD LENGTH/SHIFT] button simultaneously. The program starts, then
proceeds automatically to the end.
Backup Memory Check: If any error detected, the memory is
initialized to the default.
CPU-LSI Communication Check: If any error detected, all the LED
blinks on the front panel. To escape from error indication press the
[FREQ/CH SEL] and [WORD LENGTH/SHIFT] button simultaneously,
then contact the nearest service center.
LED Check: All the LED lights on the front panel.
Front Panel Button Check: Press the button one by one, the LED
responding to the button turns off.
DIP Switch Check:
AD96: The bar graph LEDs (10-point) on the
8th channel indicate the
switch status. The LED lights when the switch is On, or does not light
when it is Off. DIP switch #1 status is displayed in the PEAK position
and descending #
2, 3, and so forth.
AD96M: PEAK/SIGNAL LEDs of eight channels indicate the switch
status. The LED lights when the switch is On, or does not light when
it is Off. DIP switch #1 status is displayed in the CH 1 position and
corresponding to #
2, 3, and so forth.
•Turn off the AD converter when the diagnosis is completed.
K
eylock
To protect the settings from mischief or mis-operation, this setting enables
the buttons on the panel to be inactive. Pressing buttons is ignored when this
is set to On except rotating trimmers and power On/Offs.
• To activate Key Lock turn on the POWER switch while holding down the
[CLOCK/CAL] and [WORD LENGTH/SHIFT] buttons simultaneously.
• To quit Key Lock press ]WORD LENGTH/SHIFT] button for 2 seconds or
more.