EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
33
WHITE/BLUE
RPM RIGHT
STANDARD
VOLTAGE RPM
RIGHT
If connected to Rotax engine
(5
th
trigger coil), remove 30K
resistor.
If not connected to Rotax, no
changes required.
34
BLUE
EMS-D10
EMS-D120
DSAB B
FlightDEK-D180
UNUSED
LOW VOLTAGE
RPM LEFT
New capability - tachometer
signals < 10V).
35
GREEN
EMS-D10
EMS-D120
DSAB A
FlightDEK-D180
UNUSED
LOW VOLTAGE
RPM RIGHT
New capability - tachometer
signals < 10V).
36
BLUE
EMS-D10
EMS-D120
DSAB B
FlightDEK-D180
UNUSED
GENERAL
PURPOSE
THERMOCOUPLE
2 + (J OR K)
New capability – Type J (CHT)
or Type K (EGT) Thermocouple +
input. Remove Blue wire, then
install:
Type J (CHT) White wire
or
Type K (EGT) Yellow wire
37
GREEN
EMS-D10
EMS-D120
DSAB A
FlightDEK-D180
UNUSED
GENERAL
PURPOSE
THERMOCOUPLE
2 - (J OR K)
New capability – Type J (CHT)
or Type K (EGT) Thermocouple –
(minus) input. Remove Green
wire, then install:
Type J (CHT) Red wire
or
Type K (EGT) Red wire
Notes:
1. All Ground pins (3, 5, 13, 16, 17, or 30) in the SV-EMS-220 are common.
2. As discussed in the SkyView System Installation Guide, connect one of the Ground wires
to the engine block to provide a common (reference) ground for sensors that use the
engine block for ground.