EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
1
RED
EMS-D10
EMS-D100
MASTER POWER
FlightDEK-D180
UNUSED
VOLTMETER 1
(0-30 VOLTS DC)
New capability; now used for
monitoring voltage.
In EMS-D10 and EMS-D100, this
wire provided power input. In
the FlightDEK-D180, power
input was from the 25-pin EFIS
connector, Pin 1.
If connected to avionics power
(EMS-D10, EMS-D100), OK for
that connection to remain. For
a FlightDEK-D180, connect this
wire for monitoring voltage.
2
YELLOW
(or no wire
installed)
EMS-D10
EMS-D100
KEEP ALIVE
FlightDEK-D180
UNUSED
VOLTMETER 2
(0-30 VOLTS DC)
New capability; now used for
monitoring voltage at a second
point in the electrical system.
In EMS-D10 and EMS-D100, this
wire provided KEEP ALIVE
power input. In FlightDEK-
D180, KEEP ALIVE power input
was from the 25-pin EFIS
connector, Pin 2.
If connected to (backup)
avionics power (EMS-D10, EMS-
D100), OK for that connection
to remain. For a FlightDEK-
D180, connect this wire for
monitoring voltage.
3
BLACK
GROUND (FOR
POWER INPUT)
SIGNAL
GROUND
New capability - now a ground
connection available for
connection to sensors.