D10 and D100 Series Conversion To SkyView Guide – Rev D
Page 21
EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
4
VIOLET/BLUE
GENERAL
PURPOSE INPUT
1
GENERAL
PURPOSE INPUT
1 (TYPE A)
If connected to Dynon P/N
100413-000 Carb Temp Sensor,
remove the 1K resistor installed
between this pin and Pin 18
(+5V Output).
If connected to Dynon 100411-
000 Pressure Sensor for
monitoring coolant, remove the
1K resistor installed between
this pin and Pin 18 (+5V
Output).
If connected to Dynon 100409-
000 or 100409-001 Oil /
Coolant Temp Sensor for
monitoring coolant, remove the
1K resistor installed between
this pin and Pin 18 (+5V
Output).
If connected to Rotax CHT,
remove the 1.21K resistor
between this pin and Pin 18
(+5V Output).
If connected to Dynon 100433-
000 OAT, see Guidelines For
Connection of Installed OAT to
SV-ADAHRS-200/201 OAT
Input.
5
BLACK
GROUND
SIGNAL
GROUND
No changes required.
6
WHITE/YELLOW
OIL PRESSURE
GENERAL
PURPOSE INPUT
11 (TYPE B)
No changes required.
7
WHITE/BROWN
OIL
TEMPERATURE
GENERAL
PURPOSE INPUT
12 (TYPE A)
No changes required.
8
BROWN
FUEL PRESSURE
GENERAL
PURPOSE INPUT
4 (TYPE C)
If connected to Rotax P/N
956413 (Honeywell) or Rotax
P/N 456180, remove 200 ohm
resistor between Pin 8 and
ground.