Dynon Avionics D100 Series to SkyView Conversion Guide User Manual
Page 26
D10 and D100 Series Conversion To SkyView Guide – Rev D
Page 26
EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
26
GREEN/RED
MANIFOLD
PRESSURE
MANIFOLD
PRESSURE
No changes required.
27
(NO WIRE)
GENERAL
PURPOSE
THERMOCOUPLE
+ (J OR K)
GENERAL
PURPOSE
THERMOCOUPLE
1 + (J OR K)
No changes required.
28
(NO WIRE)
GENERAL
PURPOSE
THERMOCOUPLE
- (J OR K)
GENERAL
PURPOSE
THERMOCOUPLE
1 + (J OR K)
No changes required.
29
YELLOW/GREEN
EMS ALARM
LIGHT OUTPUT
EMS ALARM
LIGHT OUTPUT
No changes required.
30
BLACK
PC SERIAL
GROUND
GROUND
New capability - now a sensor
ground. Cut off the 9-pin
connector to use this wire.
If connected to PC (firmware,
data logs), no longer required.
31
WHITE/ORANGE
AUDIO OUTPUT
GENERAL
PURPOSE INPUT
13 (TYPE C)
New capability – now a General
Purpose input.
If connected to audio output,
reroute this wire to SkyView
display. Because EFIS Audio
was mono, connect this wire to
both SkyView Display
PIN 13 – AUDIO OUTPUT LEFT
and
PIN 31 – AUDIO OUTPUT RIGHT
If a 10K potentiometer was
installed on this to adjust
volume, remove it (SkyView has
internal volume adjustment).
32
WHITE/GREEN
RPM LEFT
STANDARD
VOLTAGE RPM
LEFT
If connected to Rotax engine
(5
th
trigger coil), remove 30K
resistor.
If not connected to Rotax, no
changes required.