Dynon Avionics D100 Series to SkyView Conversion Guide User Manual
Page 18
D10 and D100 Series Conversion To SkyView Guide – Rev D
Page 18
EFIS D25
Female
Connector
Pin No.
EFIS D25
Connector
Wire
Color
EFIS Function
Notes for conversion to SkyView SV-HARNESS-D37
21
WHITE
SERIAL 2 GROUND
If this wire was used for connection to transponder (or
Dynon 100362-000 Serial-to-Gray Code Encoder
Converter Module), reroute this wire to SkyView
Display Master Ground, common with SV-HARNESS-
D37 black wires on Pins 21 & 22
22
YELLOW
SERIAL 1 - RX
If this wire was used for connection to PC, no longer
required; remove this wire.
If this wire was used for connection to GPS or NAV
radio, reroute this wire to SkyView Display Serial Port
RX.
23
WHITE /
GREEN
EDC-D10A DATA A
Not used in SkyView system.
Remove this wire.
24
WHITE
EDC-D10A GND
Not used in SkyView system.
Remove this wire.
25
This pin is not used, and thus not populated in the EFIS Connector – no wire.