Dynon Avionics D100 Series to SkyView Conversion Guide User Manual
Page 23
D10 and D100 Series Conversion To SkyView Guide – Rev D
Page 23
EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
19
WHITE/BLACK
SERIAL B RX
FUEL FLOW 2
New capability – now a second
(differential) fuel flow sensor
input. If connected, SkyView
can display differential fuel
flow.
If connected to GPS or NAV
input, reroute connection to
SkyView display(s) serial port
RX.
20
ORANGE/BROWN
FUEL LEVEL
1 / LEFT
GENERAL
PURPOSE INPUT
9 (TYPE A)
If connected to resistance type
(float) fuel level sensor, no
changes required.
If connected to capacitive type
(voltage output) fuel level
sensor, reroute connection to
Pin 8, Pin 22, Pin 23, or Pin 31.
21
ORANGE/BLUE
FUEL LEVEL
2 / RIGHT
GENERAL
PURPOSE INPUT
10 (TYPE A)
If connected to resistance type
(float) fuel level sensor, no
changes required.
If connected to capacitive type
(voltage output) fuel level
sensor, reroute connection to
Pin 8, Pin 22, Pin 23, or Pin 31.