Dynon Avionics D100 Series to SkyView Conversion Guide User Manual
Page 25
D10 and D100 Series Conversion To SkyView Guide – Rev D
Page 25
EMS D37
Female
Connector
Pin No.
EMS D37
Connector Wire
Color
EMS Function
SV-EMS-220
Function
Sensor / Wiring Conversion To
SV-EMS-220
23
VIOLET/GREEN
GENERAL
PURPOSE INPUT
3
GENERAL
PURPOSE INPUT
3 (TYPE C)
New capability; can now accept
voltage input similar to Pins 8,
22, and 31 (Enhanced General
Purpose Inputs 4, 2, and 13
respectively).
If connected to Dynon P/N
100413-000 Carb Temp Sensor,
remove the 1K resistor installed
between this pin and Pin 18
(+5V Output).
If connected to Dynon 100411-
000 Pressure Sensor for
monitoring coolant, remove the
1K resistor installed between
this pin and Pin 18 (+5V
Output).
If connected to Dynon 100409-
000 or 100409-001 Oil /
Coolant Temp Sensor for
monitoring coolant, remove the
1K resistor installed between
this pin and Pin 18 (+5V
Output).
If connected to Rotax CHT,
remove the 1.21K resistor
between this pin and Pin 18
(+5V Output).
If connected to Dynon 100433-
000 OAT, see Guidelines For
Connection of Installed OAT to
SV-ADAHRS-200/201 OAT
Input.
24
ORANGE/GREEN
AMPS
TRANSDUCER
+
AMPS
TRANSDUCER
+
If connected to Dynon 100412-
000: no changes required.
If connected to GRT-CS-01:
Green (output) wire must be
moved to Pin 8 or Pin 22 or Pin
31 – see SkyView System
Installation Guide
25
ORANGE/VIOLET
AMPS
TRANSDUCER
-
AMPS
TRANSDUCER
-
No changes required.