Installation and operating instructions – Pilz PSENme 4.2 / 4A User Manual
Page 5
Installation and Operating Instructions
Date of issue: 31.01.2005 / Page 5 of 5
Document: 0800000424_en / Version: 1
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, D-73760 Ostfildern, Deutschland
Phone: +49 711 3409-0, Fax: +49 711 3409-133, E-Mail: [email protected], www.pilz.com
Template : 0850174292 Orig. 2
Start-up
Mechanical function test:
Actuate the safety guard und check the proper switching function.
Electrical function test in the safety control circuit:
- Opening the safety guard shall break off the energy of the drive.
- The drive shall only be energized when the safety guard is in its closed position.
Maintenance / Inspection
The switching device is maintenance-free. For trouble-free operation and a long service life the device should be
inspected regularly. Ensure that:
- all components are secure and tight
- switching functions operate properly
- all sealing gaskets are in proper condition
- the components show no signs of tear and wear.
If defects are detected the complete switching device and the actuator have to be replaced.
Liability disclaimer
By breach of the given instructions (concerning the intended use, the safety instructions, the installation and
connection through qualified personnel and the testing of the safety function) any liability expires.