Electrical data

PSEN me4

PSEN me4.01

PSEN me4.1

PSEN me4.11

PSEN me4.2

PSEN me4.21

Switching function

1 NO/1 NC (Zb)

2 NC (Zb)

1 NO/2 NC (Zb)

Switch symbol

Rated insulation voltage

U

i

250 V AC

250 V AC

400 V AC

Conventional thermal current

I

the

10 A

10 A

5 A

Utilization category
acc. IEC/EN 60947-5-1

AC-15, U

e

/I

e

240 V/3A

AC-15, U

e

/I

e

240 V/3 A

AC-15, U

e

/I

e

240 V/1,5 A

Type of short-circuit protection

10 A gL/gG

6 A gL/gG

6 A gL/gG

Melting fuse acc. IEC/EN 60947-5-1, annex K

Forced disconnection (N.C.)

IEC/EN 60947-5-1

Degree of protection

II, protective insulation

Mechanical data

Enclosure

Thermoplastic, glass fiber reinforced (UL94-V0)

Cover

Thermoplastic, glass fiber reinforced (UL94-V0)

Ambient air temperature

-30°C to +80°C, -22°F to +176°F

Cable entry

1 x M20x1,5

Protection class

IP65 acc. EN 60529; DIN VDE 0470 T1

Weight

≈ 0,13 kg

Actuating device

4AS

Actuator Separate

actuator (St stainless)

Actuating radius

150 mm

Extraction force

Standard 10 N

PSEN me4.01, PSEN me4.11, PSEN me4.21 50 N

Mechanical life

1 x 10

6

switching cycles

Mechanical life, extended actuation force

1 x 10

5

switching cycles

Switching frequency

30/minute

Standards

VDE 0660 T100, DIN EN 60947-1, IEC 60947-1

VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1

GS-ET-15

EU-Conformity

Approvals

BG (applied for)

UL/CSA A300 (applied for) for PSEN me4,
PSEN me4.01, PSEN me4.1, PSEN me4.11

UL/CSA B300 (applied for) for PSEN me4.2,
PSEN me4.21

This manual is related to the following products: