DLE DC4 n m t
[Function]
Outputting specified pulse in real-time.
[Code]
<10>H<14>H
[Range]
n=1, m=0,1
1
t
8
[Outline]
A signal specified with “t” is output to the connector pin
specified with “m”.
m
Connector pin
0
Pin No. 2 of drawer Kick-Out Connector
1
Pin No. 5 of drawer Kick-Out Connector
[Details]
• On-time and off-time are set at t
× 100 msec, respectively.
• In case an error occurred during the processing of this
command, the command is ignored.
• In case (ESC p or DLE DC4 under execution), during the
processing of this command the command is ignored.
• This command will be processed as it is received.
• In specification of serial interface, the command is executed
even in offline, reception buffer full and error conditions.
• In specification of parallel interface, this command cannot be
executed while the printer is BUSY.
• This command will be valid, even if specifying the printer is
invalid due to the selection of peripheral units (ESC =).
[Caution]
• If the same data string as this command is present in the
received data, the printer operates the same way as with this
command. The user should, therefore, be careful.
• The command cannot be inserted in another string of
commands which consist of codes of 2 bytes or more.
[Reference]
ESC p