Smart Power Systems LR Series User Manual
Page 38

Smart Power
®
Systems
A. C. MODULAR GENERATOR SYSTEM
Page 37 of 49
a. Press the Mode switch repeatedly until one of the screens shown in Figure 29
appears.
b. While holding the Mode switch down, press and release the On/Off switch three
times in succession, then release the Mode switch. The Oil Filter Fault display
will be removed and replaced by another screen. The fault has been cleared
and the timer reset. Note: Perform this step every time the filter is changed.
c. When the timer has been reset, the system automatically enters purge mode to
purge any entrapped air from the hydraulic lines. See Figure 11. The system
must be purged for 30 minutes.