beautypg.com

Smart Power Systems LR Series User Manual

Page 30

background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 29 of 49

Step c: Press On/Off to
answer “yes” and
override the shutdown.

Example of Command & Control Center

in hot oil fault override confirmation

Figure 20


c. If your answer was “yes” in the previous step, the confirmation screen shown in

Figure 20 will be displayed. Again note the y and n labels below the Mode and
On/Off switches. Press the On/Off switch to answer “yes” and override the
shutdown. Press Mode to answer “no” and proceed to the oil temperature
display.


Note: The hydraulic oil is rated for operation at temperatures between -19°F
and 175°F. If you override the system and command it to operate at oil
temperatures above 195°F, the system output power may degrade and you will
void the system’s warranty.

9.

If the system detects an insufficient level of hydraulic fluid in the reservoir, it will
begin displaying an alarm. If the generator was running when the fault is detected,
it will automatically be shut down in 30 minutes unless the shutdown is overridden.
To override the shutdown, perform the following steps:

Note: The oil level in the reservoir must be low for this procedure to work.

Step a: Press Mode to
cause

rvn

and the

y

and

n labels to appear.

Step b: Press On/Off to
answer “yes” and make
the next screen appear.

Example of Command & Control Center in low oil fault override

Figure 21