2 special format 2 – Rice Lake TA Series, Rice Lake Weighing Systems User Manual
Page 73

RL-TA Series Operation Manual 69
17.5.2 Special format 2
This output format is applied when [
7.1F 42] is selected in Function 1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
S1 S2 S3 SP D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 SP U1 U2 U3 CR LF
Stability
information
S
pac
e
Measurement data (including polarity and decimal
point)
S
pac
e
Unit
(One to three
characters)
Termi-
nator
S1~S3 (three character): Stable: [S
S] (53H) (20H) (53H), Unstable: [S
D]: (53H) (20H) (44H)
SP (One character): Space [ ](20H)
D1~D10 (10 character): Set value error Polarity plus/zero: Space [ ] (20H), Minus: [-] (2DH)
numerical value [0 to 9] (30H–39H), and decimal point (2EH)
* Numerical values are right-aligned.
A space (20H) is used when there is no numerical value.
SP(One character):Space[ ](20H)
U1~U3 (One to three character): Unit
Unit
Output
ASCII code
mg
mg
(6DH) (67H)
g
g
(67H)
carat
ct
(63H) (74H)
ounce
oz
(6FH) (7AH)
pound
lb
(6CH) (62H)
troy ounce
ozt
(6FH) (7AH) (74H)
penny weight
dwt
(64H) (77H) (74H)
grain
gr
(67H) (72H)
tael(Hong Kong)
tlh
(74H) (6CH) (68H)
tael(SG)
tls
(74H) (6CH) (73H)
tael(Taiwan)
tlt
(74H) (6CH) (74H)
momme
mom
(6DH) (6FH) (6DH)
tola
tla
(74H) (6CH) (61H)
parts counting
pcs
(70H) (63H) (73H)
percentage weighing
%
(25H)
unit converting
#
(23H)
* This format has a variable length, with the number of characters varying from one to three depending on
the unit.
Example:
[123.4567g]
: S
S
123.4567
g
[
o - Err]
: S
+
[
u - Err]
: S
-
(**H) : ASCII code
:
Space