2 saving and transferring data, 1 saving indicator data to a personal computer, Saving indicator data to a personal computer – Rice Lake SURVIVOR 420HE Hostile Environment - Installation Manual User Manual
Page 38

34
420HE Installation Manual
5.2
Saving and Transferring Data
Connecting a personal computer to the
420HE
EDP
port allows you to save indicator configuration data to 
the PC or to download configuration data from the PC 
to an indicator. The following sections describe the 
procedures for these save and transfer operations.
5.2.1
Saving Indicator Data to a Personal Computer
Configuration data can be saved to a personal computer 
connected to the EDP port. The PC must be running a 
communications program such as PROCOMMPLUS
®
.
See Section 2.3.3 on page 8 for information about 
serial communications wiring and EDP port pin 
assignments.
When configuring the indicator, ensure that the values 
set for the BAUD and BITS parameters on the SERIAL 
menu match the baud rate, bits, and parity settings 
configured for the serial port on the PC. Set the 
PRNDEST parameter to EDP.
To save all configuration data, place the indicator in 
setup mode and send the DUMPALL EDP command to 
the indicator. The 
420HE
responds by sending all
configuration parameters to the PC as ASCII-formatted 
text. 
5.2.2
Downloading Configuration Data from PC to 
Indicator
Configuration data saved on a PC or floppy disk can be 
downloaded from the PC to an in dicator. This 
procedure is useful when a number of indicators with 
similar configurations are set up or when an indicator is 
replaced.
To download configuration data, connect the PC to the 
EDP port as described in Section 5.2.1. Place the 
i n d i c a t o r i n s e t u p m o d e a n d u s e t h e P C 
c o m m u n i c a t i o n s s o f t w a r e t o s e n d t h e s a v e d 
configuration data to the indicator. When transfer is 
complete, calibrate the indicator as described in 
Section 4.0.
NOTES:
•
Calibration settings are included in the 
configuration data downloaded to the indicator. 
I f t h e r e c e i v i n g i n d i c a t o r i s a d i r e c t 
replacement for another 
420HE
and the
attached scale is not changed, recalibration is 
not required.
•
When downloading configurations that include 
changed serial communications settings, edit 
the data file to place the serial communications 
changes at the end of the file. Communication 
between the PC and indicator will be lost once 
the indicator receives settings for baud rate 
(BAUD parameter) or data bits and parity 
(BITS parameter) that do not match those 
configured for the PC. 
